Malfunction of cardiac devices after radiotherapy without direct exposure to ionizing radiation: Mechanisms and experimental data

ZECCHIN, MASSIMO
•
MOREA, GAETANO
•
SEVERGNINI, MARA
altro
SINAGRA, GIANFRANCO
2016
  • journal article

Periodico
EUROPACE
Abstract
AIMS: Malfunctions of cardiac implantable electronical devices (CIED) have been described after high-energy radiation therapy even in the absence of direct exposure to ionizing radiation, due to diffusion of neutrons (n) causing soft errors in inner circuits. The purpose of the study was to analyse the effect of scattered radiation on different types and models of CIED and the possible sources of malfunctions. METHODS AND RESULTS: Fifty-nine explanted CIED were placed on an anthropomorphous phantom of tissue-equivalent material, and a high-energy photon (15 MV) radiotherapy course (total dose = 70 Gy) for prostate treatment was performed. All devices were interrogated before and after radiation. Radiation dose, the electromagnetic field, and neutron fluence at the CIED site were measured. Thirty-four pacemakers (PM) and 25 implantable cardioverter-defibrillators (ICD) were analysed. No malfunctions were detected before radiation. After radiation a software malfunction was evident in 13 (52%) ICD and 6 (18%) PM; no significant electromagnetic field or photon radiations were detected in the thoracic region. Neutron capture was demonstrated by the presence of the (198)Au((197)Au + n) or (192)Ir((191)Ir + n) isotope activation; it was significantly greater in ICD than in PM and non-significantly greater in damaged devices. A greater effect in St Jude PM (2/2 damaged), Boston (9/11), and St Jude ICD (3/6) and in older ICD models was observed; the year of production was not relevant in PM. CONCLUSION: High-energy radiation can cause different malfunctions on CIED, particularly ICD, even without direct exposure to ionizing radiation due to scattered radiation of neutrons produced by the linear accelerator.
DOI
10.1093/europace/euv250
WOS
WOS:000371244400019
Archivio
http://hdl.handle.net/11368/2870975
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84960445126
http://europace.oxfordjournals.org/content/early/2015/09/01/europace.euv250
Diritti
open access
license:digital rights management non definito
license:digital rights management non definito
FVG url
https://arts.units.it/request-item?handle=11368/2870975
Soggetti
  • CIED malfunction

  • Implantable cardiover...

  • Pacemaker

  • Radiotherapy

  • Scattered radiation

  • Soft error

  • Cardiology and Cardio...

  • Physiology (medical)

Scopus© citazioni
34
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
41
Data di acquisizione
Mar 23, 2024
Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback