Logo del repository
  1. Home
 
Opzioni

OCT Intensity of the Region between Outer Retina Band 2 and Band 3 as a Biomarker for Retinal Degeneration and Therapy

Zeng, Yong
•
Gao, Shasha
•
Li, Yichao
altro
Qian, Haohua
2024
  • journal article

Periodico
BIOENGINEERING
Abstract
Optical coherence tomography (OCT) is widely used to probe retinal structure and function. This study investigated the outer retina band (ORB) pattern and reflective intensity for the region between bands 2 and 3 (Dip) in three mouse models of inherited retinal degeneration (Rs1KO, TTLL5KO, RPE65KO) and in human AMD patients from the A2A database. OCT images were manually graded, and reflectivity signals were used to calculate the Dip ratio. Qualitative analyses demonstrated the progressive merging band 2 and band 3 in all three mouse models, leading to a reduction in the Dip ratio compared to wildtype (WT) controls. Gene replacement therapy in Rs1KO mice reverted the ORB pattern to one resembling WT and increased the Dip ratio. The degree of anatomical rescue in these mice was highly correlated with level of transgenic RS1 expression and with the restoration of ERG b-wave amplitudes. While the inner retinal cavity was significantly enlarged in dark-adapted Rs1KO mice, the Dip ratio was not altered. A reduction of the Dip ratio was also detected in AMD patients compared with healthy controls and was also positively correlated with AMD severity on the AMD score. We propose that the ORB and Dip ratio can be used as non-invasive early biomarkers for retina health, which can be used to probe therapeutic gene expression and to evaluate the effectiveness of therapy.
DOI
10.3390/bioengineering11050449
WOS
WOS:001232968800001
Archivio
https://hdl.handle.net/11368/3101920
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85194360755
https://www.mdpi.com/2306-5354/11/5/449
Diritti
open access
license:creative commons
license:digital rights management non definito
license uri:http://creativecommons.org/licenses/by/4.0/
license uri:iris.pri00
FVG url
https://arts.units.it/bitstream/11368/3101920/1/bioengineering-11-00449.pdf
Soggetti
  • AMD patient

  • gene therapy

  • mouse model

  • optical coherence tom...

  • outer retina band

  • reflective intensity

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback