Effect of external PEEP in patients under controlled mechanical ventilation with an auto-PEEP of 5 cmH2O or higher

Natalini, Giuseppe
•
Tuzzo, Daniele
•
Rosano, Antonio
altro
Ventilab group
2016
  • journal article

Periodico
ANNALS OF INTENSIVE CARE
Abstract
Background: In some patients with auto-positive end-expiratory pressure (auto-PEEP), application of PEEP lower than auto-PEEP maintains a constant total PEEP, therefore reducing the inspiratory threshold load without detrimental cardiovascular or respiratory effects. We refer to these patients as "complete PEEP-absorbers." Conversely, adverse effects of PEEP application could occur in patients with auto-PEEP when the total PEEP rises as a consequence. From a pathophysiological perspective, all subjects with flow limitation are expected to be "complete PEEP-absorbers," whereas PEEP should increase total PEEP in all other patients. This study aimed to empirically assess the extent to which flow limitation alone explains a "complete PEEP-absorber" behavior (i.e., absence of further hyperinflation with PEEP), and to identify other factors associated with it. Methods: One hundred patients with auto-PEEP of at least 5 cmH(2)O at zero end-expiratory pressure (ZEEP) during controlled mechanical ventilation were enrolled. Total PEEP (i.e., end-expiratory plateau pressure) was measured both at ZEEP and after applied PEEP equal to 80 % of auto-PEEP measured at ZEEP. All measurements were repeated three times, and the average value was used for analysis. Results: Forty-seven percent of the patients suffered from chronic pulmonary disease and 52 % from acute pulmonary disease; 61 % showed flow limitation at ZEEP, assessed by manual compression of the abdomen. The mean total PEEP was 7 +/- 2 cmH(2)O at ZEEP and 9 +/- 2 cmH(2)O after the application of PEEP (p < 0.001). Thirty-three percent of the patients were "complete PEEP-absorbers." Multiple logistic regression was used to predict the behavior of "complete PEEP-absorber." The best model included a respiratory rate lower than 20 breaths/min and the presence of flow limitation. The predictive ability of the model was excellent, with an overoptimism-corrected area under the receiver operating characteristics curve of 0.89 (95 % CI 0.80-0.97). Conclusions: Expiratory flow limitation was associated with both high and complete "PEEP-absorber" behavior, but setting a relatively high respiratory rate on the ventilator can prevent from observing complete "PEEP-absorption." Therefore, the effect of PEEP application in patients with auto-PEEP can be accurately predicted at the bedside by measuring the respiratory rate and observing the flow-volume loop during manual compression of the abdomen.
DOI
10.1186/s13613-016-0158-0
WOS
WOS:000379813100001
Archivio
http://hdl.handle.net/11368/2892225
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84976502768
http://annalsofintensivecare.springeropen.com/articles/10.1186/s13613-016-0158-0
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/3.0/it/
FVG url
https://arts.units.it/bitstream/11368/2892225/1/art%3A10.1186%2Fs13613-016-0158-0.pdf
Soggetti
  • Auto-positive end-exp...

  • Dynamic hyperinflatio...

  • Flow limitation

  • Mechanical ventilatio...

  • Positive end-expirato...

  • Respiratory rate

  • Critical Care and Int...

Scopus© citazioni
7
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
9
Data di acquisizione
Mar 27, 2024
Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback