Uncalibrated arterial pulse cardiac output measurements in patients with moderately abnormal left ventricular function.

Vetrugno L
•
COSTA, Maria Gabriella
•
Spagnesi L
altro
DELLA ROCCA, Giorgio
2011
  • journal article

Periodico
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA
Abstract
OBJECTIVE: The aim of the study was to evaluate the accuracy and precision of the Vigileo/FloTrac system (Edwards Lifesciences, Irvine, CA) when compared with the intermittent cardiac output and continuous cardiac output measurements obtained from pulmonary arterial catheters in patients with moderately abnormal left ventricular function undergoing elective coronary artery bypass graft surgery. DESIGN: A prospective, observational study. SETTING: Tertiary university hospital. PARTICIPANTS: Twenty patients with moderately abnormal left ventricular function undergoing coronary artery bypass graft surgery were enrolled. MEASUREMENTS AND RESULTS: Data were collected before the induction of anesthesia (T1), after the induction of anesthesia (T2), before cardiopulmonary bypass with an open chest (T3), after cardiopulmonary bypass (T4), after sternal closure (T5), on intensive care unit admission (T6), and at 6 hours (T7) and 12 hours after surgery (T8). A total of 360 data measurements were collected; the mean bias between intermittent cardiac output (ICO) and arterial pressure cardiac output (APCO) was -0.50 ± 1.72 L/min, and the percentage error (PE) was 37.00%. The mean difference between CCO and APCO was -0.06 ± 1.84 L/min, and the PE was 37.80%. The correlation between ΔICO and ΔAPCO was r = 0.7; the correlation between ΔCCO and ΔAPCO was r = 0.73. In the intraoperative period, the mean bias between ICO and APCO was -0.41 ± 1.75 L/min, and the PE was 40.87%. The mean difference between CCO and APCO was -0.18 ± 1.90 L/min, and the PE was 41.48%. In the postoperative period, the mean bias between ICO and APCO was -0.56 ± 1.70 L/min, and the PE was 34.43%. The mean difference between CCO and APCO was -0.36 ± 1.76 L/min, and the PE was 34.87%. CONCLUSIONS: In cardiac surgical patients with moderately abnormal left ventricular function, the Vigileo/FloTrac 2nd generation software sensor device showed mild intraoperative and postoperative agreement when compared with a pulmonary arterial catheter.
DOI
10.1053/j.jvca.2010.07.001
WOS
WOS:000287065200010
Archivio
http://hdl.handle.net/11390/900774
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-79251597426
Diritti
closed access
Soggetti
  • cardiac output

  • arterial waveform ana...

  • coronary artery bypas...

  • left ventricular func...

  • ejection fraction

Scopus© citazioni
19
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
24
Data di acquisizione
Mar 26, 2024
Visualizzazioni
3
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback