Platelet-Rich Plasma (PRP) Before Clinical Application: Qualitative Flow Cytometric Analysis and Enzyme-Linked Immunosorbent Assay (ELISA) Exploring Platelet Activation and TGFβ Release During Storage

Fulvia Costantinides
•
Violetta Borelli
•
Alvise Camurri Piloni
altro
Michele Maglione
2026
  • journal article

Periodico
BIOMEDICINES
Abstract
Background/Objectives: In clinical practice today, platelet concentrates are often used for topical surgical applications. They are biomaterials that can accelerate healing processes associated with oral and maxillofacial surgery as well as in several other clinical applications through the action of growth factors released by platelets at the surgical site. However, in most cases, the exact quantification of the released growth factors is challenging in both the short and long term. The aim of this study was to determine if early platelet activation and degranulation occur during the collection and utilization of platelet-rich plasma (PRP) in the surgical room, where, before its application, PRP undergoes a procedure of gelification via reactions with procoagulant agents. Methods: PRP was prepared from the blood samples of 39 patients following the modified Whitman protocol. The samples were then analyzed at four different time points (1, 6, and 24 h during preparation and clinical application in the surgery room) using flow cytometry and enzyme-linked immunosorbent assays (ELISAs) to investigate the platelet activation/degranulation and TGFβ release in the supernatant (SN) during storage and clinical application. The mean platelet count in the whole blood was 267.5 ± 48.58 × 103/mL (range: 189–334 × 103/mL), and the mean concentration was 2925.5 ± 833.37 × 103/mL (range: 748–3453 × 103/mL). Results: The activation and degranulation of platelet cells (measured via monoclonal antibodies: CD62p and CD63, respectively) demonstrated a progressive increase at 1 h, 6 h, 24 h, and after gelification. The TGFβ dosage in the supernatant (SN) at different times exhibited a similar trend, with a mean release of 18.36 ng/mL at 1 h, 21.96 ng/mL at 6 h, and 29.45 ng/mL at 24 h. After the gelification of the PRP, a significant reduction was observed, with a value of 15.52 ng/mL. Conclusions: The results reveal that the protocol used for the preparation, storage, and application of the PRP ensures a good-quality hemoderivative and that the platelet concentrate must be applied with the correct timing to support tissue healing processes.
DOI
10.3390/biomedicines14020353
WOS
WOS:001700705900001
Archivio
https://hdl.handle.net/11368/3129898
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-105031354794
https://www.mdpi.com/2227-9059/14/2/353
https://ricerca.unityfvg.it/handle/11368/3129898
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
FVG url
https://arts.units.it/bitstream/11368/3129898/1/biomedicines-14-00353.pdf
Soggetti
  • ELISA

  • flow cytometry

  • platelet-rich plasma

  • TGF-β

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback