Logo del repository
  1. Home
 
Opzioni

Antiphospholipid IgG Certified Reference Material ERM®-DA477/IFCC: a tool for aPL harmonization?

Claudia Grossi
•
Liesbet Deprez
•
Caterina Bodio
altro
Pier Luigi Meroni
2025
  • journal article

Periodico
CLINICAL CHEMISTRY AND LABORATORY MEDICINE
Abstract
The Certified Reference Material (CRM) ERM®-DA477/IFCC is a new polyclonal IgG anti-beta2-glycoprotein I (anti-β2GPI) material for the harmonization of the laboratory diagnosis of antiphospholipid syndrome (APS). We evaluated CRM's ability to represent the heterogeneity of APS patient anti-β2GPI antibodies and to calibrate IgG anti-β2GPI methods. We characterized CRM for its reactivity against domain-1, using the QUANTA Flash® β2GPI-domain-1 assay, and against domains-4-5 of β2GPI, and single-domain-deleted β2GPI molecules using in-house ELISAs. We used QUANTA Lite® ELISA, QUANTA Flash® CLIA, and EliATM FEIA methods to evaluate the CRM's anti-Cardiolipin (anti-CL) activity. Four anti-β2GPI IgG methods (in-house and QUANTA Lite® ELISA, QUANTA Flash® CLIA, and EliATM FEIA) were also used to evaluate the CRM's calibration efficacy, alongside 133 clinical samples (CSs) and 99 controls. The CRM showed high anti-domain-1 activity and no anti-domain-4-5 activity at the recommended assay dilution. The domain-dependent-β2GPI reactivity profiles were comparable with full-blown APS. There was acceptable dilution linearity for anti-CL assays with R2 ranging from 0.957 to 0.997. For the four anti-β2GPI IgG assays, calibration with the CRM led to a good comparability of the average result of CSs for two of the assays. New cut-offs calculated from this work improved comparability in quantitative results between three of the assays: 85% concordance with CRM compared to 66% concordance with assay-specific-calibration. The CRM is representative of patient anti-β2GPI/CL heterogeneity and should improve anti-β2GPI IgG method harmonization. However, the level of achievable method harmonization is affected by differences in the selectivity among the assays.
DOI
10.1515/cclm-2025-0032
WOS
WOS:001448003700001
Archivio
https://hdl.handle.net/11368/3108438
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-105000897090
https://www.degruyterbrill.com/document/doi/10.1515/cclm-2025-0032/html
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
FVG url
https://arts.units.it/bitstream/11368/3108438/3/10.1515_cclm-2025-0032 (1).pdf
Soggetti
  • anti-cardiolipin

  • anti-β2GPI

  • antiphospholipid synd...

  • aPL-heterogeneity

  • Certified Reference M...

  • method-calibration

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback