Logo del repository
  1. Home
 
Opzioni

Cone beam computed tomography for the assessment of linear scleroderma of the face

Di Giovanni C.
•
Puggina S.
•
Meneghel A.
altro
Zulian F.
2018
  • journal article

Periodico
PEDIATRIC RHEUMATOLOGY ONLINE JOURNAL
Abstract
Background: To date, standardized methods for assessing the disease progression of linear scleroderma of the face (LSF) are lacking. Objectives: We investigated whether Cone Beam Computed Tomography (CBCT) may represent a reliable tool for assessing linear scleroderma of the face (LSF). Methods: Ten patients with LSF and five age-matched controls underwent CBCT assessment. The transverse sections at three anatomic levels of the maxillofacial bones were analyzed. Measurements of soft tissue and total thickness of both affected and unaffected side of the face were made by a standardized methodology. Six raters evaluated CBCTs twice and blindly one from the other. The intra- and inter-rater reliability was assessed by the Intraclass Correlation Coefficient (ICC). Results: CBCT was fast and well tolerated by the patients. The inter-rater concordance for the total thickness was excellent, mean ICC 0.75 for patients, 0.89 for controls. The mean ICC for soft tissue thickness was 0.49 for patients, 0.66 for controls. 58.3% of the measurements for patients and 91.2% of those for controls showed excellent ICC results (≥ 0.75). The intra-rater concordance resulted optimal (ICC 0.77-0.99). Conclusions: CBCT is a reliable technique to assess skin and bony changes of LSF.
DOI
10.1186/s12969-017-0218-5
WOS
WOS:000419194500001
Archivio
https://hdl.handle.net/11390/1273725
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85042497283
https://ricerca.unityfvg.it/handle/11390/1273725
Diritti
open access
Soggetti
  • Cone beam computed to...

  • Linear scleroderma of...

  • Localized scleroderma...

  • Morphea

  • Outcome measure

  • Scleroderma en coup d...

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback