Logo del repository
  1. Home
 
Opzioni

The silicon vertex detector of the Belle II experiment

Gabrielli, A.
•
Adamczyk, K.
•
Aihara, H.
altro
Zeng, F.
2024
  • journal article

Periodico
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT
Abstract
The silicon vertex detector (SVD) is a four-layer double-sided strip detector installed at the heart of the Belle II experiment, taking data at the high-luminosity B-Factory SuperKEKB since 2019. SVD has been operating smoothly and reliably, showing a stable and above-99% hit efficiency, and a large signal-to-noise ratio in all sensors. In June 2022 the data-taking of the Belle II experiment was stopped for the Long Shutdown 1, primarily required to complete the vertex detector (VXD) with the inner two-layer DEPFET detector and to upgrade several components of the accelerator. This article reports on the excellent performance of SVD in terms of the signal-to-noise ratio, the hit position resolution, as well as the hit-time resolution. We briefly describe the challenges and delicate phases of the VXD re-installation and the SVD status for operation starting in early 2024. In SVD layer 3, which is closest to the interaction point, the average occupancy has been less 0.5%, well below the estimated limit for acceptable tracking performance. However, higher machine backgrounds are expected at increased luminosity, and so also increased hit occupancy. To enhance the robustness of offline software in a high-background environment, new algorithms of background suppression using the excellent SVD hit-time information have been developed, which allows a significant reduction of the fake rate, while preserving the tracking efficiency. With the increasing luminosity also the radiation levels are expected to increase, with possible deterioration of the sensor performance. The SVD integrated dose is estimated by the correlation of the SVD occupancy with the dose rate measured by the diamonds of the radiation monitor and beam-abort system. The effects of radiation damage are starting and in good agreement with our expectations. So far, no harmful impact due to the radiation damage on the detector performance has been observed.
DOI
10.1016/j.nima.2024.169401
WOS
WOS:001246728400001
Archivio
https://hdl.handle.net/11368/3097998
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85192222219
https://www.sciencedirect.com/science/article/pii/S0168900224003279
Diritti
closed access
license:copyright editore
license uri:iris.pri02
FVG url
https://arts.units.it/request-item?handle=11368/3097998
Soggetti
  • Belle II

  • High-luminosity

  • Silicon strip detecto...

  • Tracking

  • Vertex detector

  • I

  • Double sided

  • High-luminosity

  • Silicon Strip Detecto...

  • Silicon Vertex Detect...

  • Strip detector

  • SuperKEKB

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback