Logo del repository
  1. Home
 
Opzioni

Rebound Tonometry in Cataract Surgery: Comparison with Goldmann Applanation Tonometry

Chiara De Giacinto
•
Rossella Dâ Aloisio
•
TROVARELLI, SARA
altro
Daniele Tognetto
2018
  • journal article

Periodico
OPEN JOURNAL OF OPHTHALMOLOGY
Abstract
Purpose: to compare the rebound tonometer ICare® (RT) with the Goldmann applanation tonometer (GAT) in cataract surgery and to assess the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements. Design: retrospective, comparative study. Methods: a total of 472 patients underwent IOP measurement using RT (time 0 = RTa). GAT IOP measurement was performed 5 minutes later, followed by a second RT IOP measurement after other 5 minutes (RTa + 10 min = RTb). CCT was obtained by ultrasound pachymetry. In 106 patients IOP was measured by means of RT and GAT before clear corneal cataract surgery (RT1 and GAT1) and at one day postoperatively (RT2 and GAT2). Results: RT IOP values > 5 mmHg were overestimated, while RT IOP values < 15 mmHg were underestimated. Every 100 μm of CCT an increase of 0.97 mmHg and 0.33 mmHg was found for RT and GAT respectively. The difference between RT1 and RT2, GAT1 and GAT2, RT1 and GAT1 was not statistically significant; while the difference between RT2 and GAT2 was statistically significant (p < 0.04). The difference between RTa and RTb was not statistically significant whereas the difference between RTa and GAT and RTb and GAT was statistically significant (p < 0.001). Conclusion: our results showed a good agreement between measurements obtained with RT and GAT in pre and postoperative cataract surgery, although a significant statistically difference was found between RT and GAT measurements performed postoperatively. Moreover, CCT is a parameter to be considered for the IOP measurement, especially for values obtained with RT.
DOI
10.4236/ojoph.2018.81001
Archivio
http://hdl.handle.net/11368/2917591
http://file.scirp.org/Html/1-2020300_81599.htm
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/3.0/it/
FVG url
https://arts.units.it/bitstream/11368/2917591/1/2018_OJOph_2018010514333305.pdf
Soggetti
  • Applanation Tonometer...

  • Cataract Surgery

  • Intraocular Pressure

  • Pachymetry

  • Rebound Tonometer

Visualizzazioni
5
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback