Logo del repository
  1. Home
 
Opzioni

Comparator threshold settings and the effective pixel width of the PICASSO detector

F. C. M. Lopez
•
RIGON, LUIGI
•
FARDIN, LUCA
altro
LONGO, RENATA
2014
  • journal article

Periodico
JOURNAL OF INSTRUMENTATION
Abstract
Charge sharing plays an important role in the performance of single-photon counting microstrip detectors, since the comparator threshold defines the effective pixel width. In this contribution, the PICASSO (Phase Imaging for Clinical Application with Silicon detector and Synchrotron radiatiOn) single-photon counting microstrip detector oriented in edge-on configuration has been used to study its spatial resolution as a function of the comparator threshold. The experiment was carried out with monochromatic x-rays at the SYRMEP beamline of the Elettra synchrotron radiation facility in Trieste (Italy). The Edge Spread Function (i.e. the integral of the Line spread Function, LSF) was measured by horizontally translating vertical slits from a bar-pattern test-object in front of the detector, at four different photon energies (19, 20, 22, and 25 keV) and for several different values of the comparator threshold. The effect of charge sharing between strips on the spatial resolution has been quantified by calculating the horizontal Modulation Transfer Function (MTF). Moreover, the composite LSF from neighboring pixels was obtained: this allowed estimating the optimal threshold for each photon energy by selecting the threshold at which the composite LSF would approach unity along the entire width of the pixel. The results show that at thresholds lower than half of the photon energy, charge sharing increases the effective pixel width, causing a drop of the MTF, and it is responsible for the appearance of peaks in the composite LSF. Conversely, at thresholds higher than half of the photon energy, the effective pixel width is reduced and the spatial resolution is increased, but the collection efficiency is compromised, as demonstrated by the presence of valleys in the composite LSF.
DOI
10.1088/1748-0221/9/05/C05056
WOS
WOS:000340036100056
SCOPUS
2-s2.0-84903591938
Archivio
http://hdl.handle.net/11368/2784136
Diritti
metadata only access
Soggetti
  • Si microstrip and pad...

  • X-ray detectors

  • x-ray mammography

Web of Science© citazioni
6
Data di acquisizione
Mar 15, 2024
Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback