Logo del repository
  1. Home
 
Opzioni

Simultaneous detection of peracetic acid and hydrogen peroxide by amperometry at Pt and Au electrodes

TONIOLO, Rosanna
•
PIZZARIELLO, Andrea
•
SUSMEL, Sabina
altro
BONTEMPELLI, Gino
2006
  • journal article

Periodico
ELECTROANALYSIS
Abstract
Based on preliminary voltammetric investigations at both Pt and Au electrodes in aqueous solutions buffered at different pH values in the range 0-10, two possible profitable triple-pulse amperometric approaches were developed for determining simultaneously peroxyacetic acid (PAA) and hydrogen peroxide present in the same samples. At both surfaces a pulsed waveform applied at rotating-disc electrodes was adopted to take advantage on one hand of the optimized signal reproducibility achieved by this potential multi-step anti-fouling approach and on the other hand of the constant thickness of the diffusion layer, which is necessary when the recording of time-independent currents is desired. At a rotating-disc Pt electrode an anodic selective signal was indeed recorded for H2O2 alone, while PAA contents could be inferred only from the difference of convenient signals, since at all pHs explored its sole cathodic reaction could be observed at potentials coincident with those proper for the reduction of H2O2 too. The same pulse approach at Au electrodes instead provided totally independent signals for the two analytes considered, thus proving to be suitable for their independent detection. In fact, H2O2 alone undergoes anodic oxidation also at this surface, while the reduction of PAA occurs at potentials less cathodic than those required for H2O2. At both electrodes, the best results turned out to be achieved at pH = 0 in terms of both precision (± 2 - 4 %) and detection limits (0.2 - 0.3 mM), as well as of linear range which extended for about three orders of magnitude. The kinetics of the equilibrium involving the generation of H2O2 from the reaction of PAA with water was also evaluated, since it was suspected of making unreliable the proposed amperometric approaches.
DOI
10.1002/elan.200603641
WOS
WOS:000242025200006
Archivio
http://hdl.handle.net/11390/880884
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-33845708560
Diritti
closed access
Scopus© citazioni
12
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
14
Data di acquisizione
Mar 25, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback