Logo del repository
  1. Home
 
Opzioni

A new high-performance liquid chromatography–tandem mass spectrometry method for the determination of sunitinib and N-desethyl sunitinib in human plasma: Light-induced isomerism overtaking towards therapeutic drug monitoring in clinical routine

Marangon, Elena
•
Buzzo, Mauro
•
Posocco, Bianca
altro
Toffoli, Giuseppe
2019
  • journal article

Periodico
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Abstract
Sunitinib is approved for advanced renal cell cancer, imatinib-resistant or -intolerant gastrointestinal stromal tumors and pancreatic neuroendocrine cancers. It is prescribed at a fixed dose but its plasma exposure shows large inter-individual variations. Taking into account the narrow therapeutic window and the positive exposure-efficacy relationship, there is a robust rationale for its therapeutic drug monitoring. In fact, a target plasma concentration of sunitinib plus its active metabolite, N-desethyl sunitinib, ≥50 ng/mL was suggested. In order to quantify sunitinib and N-desethyl sunitinib in patients’ plasma, we developed and validated a new LC–MS/MS method applicable to clinical routine. In solution, sunitinib and N-desethyl sunitinib undergo to photo-isomerization and many published methods overcome this problem by conducting the entire procedures of samples collection and handling under strictly light-protection. Our method is based on a simple and fast procedure that quantitatively reconverts the E-isomer of both analytes, obtained during sample draw and processing without light-protection, into their Z-forms. Moreover, our method uses a small plasma volume (30 μL) and the analytes are extracted by a rapid protein precipitation. It was validated according to EMA-FDA guidelines. The calibration curves resulted linear (R2 always >0.993) over the concentration ranges (0.1–500 ng/mL for sunitinib, 0.1–250 ng/mL for N-desethyl sunitinib) with a good precision (within 7.7 % for sunitinib and 10.8% for N- desethyl sunitinib) and accuracy (range 95.8–102.9% for sunitinib and 92.3–106.2% for N-desethyl sunitinib). This method was applied to a pharmacokinetic study in one patient treated with sunitinib. Moreover, as incurred samples reanalysis is an established part of the bioanalytical process to support clinical studies, its assessment was performed early in order to assure that any reproducibility issues was detected as soon as possible. The percentage difference between the two runs resulted within ±20% in all the re-analysed samples for both sunitinib and N- desethyl sunitinib.
DOI
10.1016/j.jpba.2019.112949
WOS
WOS:000508752400009
Archivio
http://hdl.handle.net/11368/2953281
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85075856858
https://www.sciencedirect.com/science/article/pii/S0731708519315705
Diritti
closed access
license:copyright editore
FVG url
https://arts.units.it/request-item?handle=11368/2953281
Soggetti
  • LC-MS/MS

  • sunitinib

  • TDM

Scopus© citazioni
7
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
8
Data di acquisizione
Mar 11, 2024
Visualizzazioni
5
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback