Logo del repository
  1. Home
 
Opzioni

Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions

DELLA ROCCA, Giorgio
•
COSTA, Maria Gabriella
•
CHIARANDINI P
altro
PIETROPAOLI P.
2008
  • journal article

Periodico
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA
Abstract
Objective: This study aimed to compare continuous cardiac output (CCO) obtained using the arterial pulse wave (APCO) measurement with a simultaneous measurement of the intermittent cardiac output (ICO) and CCO obtained with a pulmonary artery catheter (PAC) in liver transplant patients. Design: A prospective, single-center evaluation. Setting: A university hospital intensive care unit. Patients: Eighteen patients after liver transplantation. Interventions: Pulmonary artery catheters were placed in all patients, and ICO and CCO were determined using thermodilution. APCO measurements were made with the Vigileo System (Edwards Lifesciences, Irvine, CA). Measurements and Main Results: The authors obtained 126 data pairs of ICO and APCO and 864 pairs of CCO and APCO. ICO data were collected after intensive care unit admission and every 8 hours until the 48th postoperative hour. CCO and APCO data were collected every hour from admission until the 48th postoperative hour. Bias and precision were 0.95 1.41 L/min for ICO versus APCO and 1.29 1.28 L/min for CCO and APCO. Bias and precision for cardiac output (CO) data pairs less than 8 L/min were 0.32 1.14 L/min between ICO and APCO and 0.71 0.98 L/min between CCO and APCO. For CO data pairs higher than 8 L/min, bias and precision were 1.79 1.54 L/min between ICO and APCO and 2.25 1.14 L/min between CCO and APCO. Conclusions: APCO enables the assessment of CO with clinically acceptable bias and precision. At higher CO levels, APCO underestimates PAC measurements and it is not as reliable as thermodilution in hyperdynamic liver transplant patients.
DOI
10.1053/j.jvca.2008.02.021
WOS
WOS:000259856000006
Archivio
http://hdl.handle.net/11390/881483
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-52149101592
Diritti
closed access
Soggetti
  • cardiac output

  • measurement technique...

  • arterial pulse contou...

  • thermodilution

  • pulmonary artery cath...

  • liver transplantation...

Scopus© citazioni
47
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
37
Data di acquisizione
Mar 22, 2024
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback