Logo del repository
  1. Home
 
Opzioni

Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter vs lithium dilution technique.

COSTA, Maria Gabriella
•
DELLA ROCCA, Giorgio
•
CHIARANDINI P
altro
PIETROPAOLI P.
2008
  • journal article

Periodico
INTENSIVE CARE MEDICINE
Abstract
OBJECTIVE: This study aimed to assess the level of agreement of both intermittent cardiac output monitoring by the lithium dilution technique (CO(Li)) and continuous cardiac output monitoring (PulseCO(Li)) using the arterial pressure waveform with intermittent thermodilution using a pulmonary artery catheter (CO(PAC)). DESIGN: Prospective, single-center evaluation. SETTING: University Hospital Intensive Care Unit. PATIENTS: Patients (n=23) receiving liver transplantation. INTERVENTION: Pulmonary artery catheters were placed in all patients and CO(PAC) was determined using thermodilution. CO(Li) and PulseCO(Li) measurements were made using the LiDCO system. MEASUREMENTS AND MAIN RESULTS: Data were collected after intensive care unit admission and every 8h until the 48th hour. A total of 151 CO(PAC), CO(Li) and PulseCO(Li) measurements were analysed. Bias and 95% limit of agreement were 0.11lmin(-1) and -1.84 to + 2.05 lmin(-1) for CO(PAC) vs. CO(Li) (r=0.88) resulting in an overall percentage error of 15.6%. Bias and 95% limit of agreement for CO(PAC) vs. PulseCO(Li) were 0.29 lmin(-1) and -1.87 to + 2.46 lmin(-1) (r=0.85) with a percentage error of 16.8%. Subgroup analysis revealed a percentage error of 15.7% for CO(PAC) vs. CO(Li) and 15.1% for CO(PAC) vs. PulseCO(Li) for data pairs less than 8 lmin(-1), and percentage errors of 15.5% and 18.5% respectively for data pairs higher than 8 lmin(-1). CONCLUSION: In patients with hyperdynamic circulation, intermittent and continuous CO values determined using the LiDCO system showed good agreement with those obtained by intermittent pulmonary artery thermodilution.
DOI
10.1007/s00134-007-0878-6
WOS
WOS:000252920100007
Archivio
http://hdl.handle.net/11390/879405
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-38849093827
Diritti
closed access
Scopus© citazioni
80
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
78
Data di acquisizione
Mar 23, 2024
Visualizzazioni
4
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback