Logo del repository
  1. Home
 
Opzioni

ECG/echo indexes in the diagnostic approach to amyloid cardiomyopathy: A head-to-head comparison from the AC-TIVE study

Pagura L.
•
Porcari A.
•
Cameli M.
altro
Arzilli C.
2023
  • journal article

Periodico
EUROPEAN JOURNAL OF INTERNAL MEDICINE
Abstract
Background and aims: The discordance between QRS voltages on electrocardiogram (ECG) and left ventricle (LV) wall thickness (LVWT) on echocardiogram (echo) is a recognized red flag (RF) of amyloid cardiomyopathy (AC) and can be measured by specific indexes. No head-to-head comparison of different ECG/echo indexes among subjects with echocardiographic suspicion of AC has yet been undertaken. The study aimed at evaluating the performance and the incremental diagnostic value of different ECG/echo indexes in this subset of patients. Methods: Electrocardiograms of subjects with LV hypertrophy, preserved ejection fraction and ≥ 1 echocardiographic RF of AC participating in the AC-TIVE study, an Italian prospective multicenter study, were independently analyzed by two cardiologists. Low QRS voltages and 8 different ECG/echo indexes were evaluated. Cohort specific cut-offs were computed. Results: Among 170 patients, 55 (32 %) were diagnosed with AC. Combination of low QRS voltages with interventricular septum ≥ 1,6 cm was the most specific (specificity 100 %, positive predictive value 100 %) ECG/echo index, while the ratio between the sum of all QRS voltages and LVWT <7,8 was the most sensitive and accurate (sensitivity 94 %, negative predictive value 97 %, accuracy 82 %). When the latter index was added to a model using easily-accessible clinical variables, the diagnostic accuracy for AC greatly increased (AUC from 0,84 to 0,95; p = 0,007). Conclusions: Among patients with non-dilated hypertrophic ventricles with normal ejection fraction and echocardiographic RF of AC, easily-measurable ECG/echo indexes, mainly when added to few clinical variables, can help the physician orient second level investigations. External validation of the results is warranted.
DOI
10.1016/j.ejim.2023.09.026
Archivio
https://hdl.handle.net/11390/1267127
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85174639064
https://ricerca.unityfvg.it/handle/11390/1267127
Diritti
metadata only access
Soggetti
  • Amyloid cardiomyopath...

  • ECG/echo indexe

  • Echocardiography

  • Electrocardiogram

  • Left ventricular ma

  • Light chain amyloidos...

  • Red flag

  • Transthyretin amyloid...

  • Voltages

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback