Logo del repository
  1. Home
 
Opzioni

Experimental optimization of the energy for breast-CT with synchrotron radiation

Oliva P.
•
Di Trapani V.
•
Arfelli F.
altro
Delogu P.
2020
  • journal article

Periodico
SCIENTIFIC REPORTS
Abstract
Breast Computed Tomography (bCT) is a three-dimensional imaging technique that is raising interest among radiologists as a viable alternative to mammographic planar imaging. In X-rays imaging it would be desirable to maximize the capability of discriminating different tissues, described by the Contrast to Noise Ratio (CNR), while minimizing the dose (i.e. the radiological risk). Both dose and CNR are functions of the X-ray energy. This work aims at experimentally investigating the optimal energy that, at fixed dose, maximizes the CNR between glandular and adipose tissues. Acquisitions of both tissue-equivalent phantoms and actual breast specimens have been performed with the bCT system implemented within the Syrma-3D collaboration at the Syrmep beamline of the Elettra synchrotron (Trieste). The experimental data have been also compared with analytical simulations and the results are in agreement. The CNR is maximized at energies around 26–28 keV. These results are in line with the outcomes of a previously presented simulation study which determined an optimal energy of 28 keV for a large set of breast phantoms with different diameters and glandular fractions. Finally, a study on photon starvation has been carried out to investigate how far the dose can be reduced still having suitable images for diagnostics.
DOI
10.1038/s41598-020-74607-7
WOS
WOS:000582705900044
Archivio
http://hdl.handle.net/11368/2973346
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85092564420
https://www.nature.com/articles/s41598-020-74607-7
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
FVG url
https://arts.units.it/bitstream/11368/2973346/4/s41598-020-74607-7.pdf
Soggetti
  • Breast CT

  • Synchrotron Radiation...

  • X-ray Phase Contrast

  • Photon Counting Detec...

  • Energy Optimization

Scopus© citazioni
5
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Web of Science© citazioni
11
Data di acquisizione
Mar 28, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback