Logo del repository
  1. Home
 
Opzioni

Radiolabeled WBC Scintigraphy in the Diagnostic Workup of Patients With Suspected Device-Related Infections

Erba PA
•
Sollini M
•
Conti U
altro
Mariani G
2013
  • journal article

Periodico
JACC. CARDIOVASCULAR IMAGING
Abstract
OBJECTIVES The aim of this study was to investigate the diagnostic performance of Tc-99m-hexamethypropylene amine oxime labeled autologous white blood cell (Tc-99m-HMPAO-WBC) scintigraphy in patients with suspected infections associated with cardiovascular implantable electronic devices (CIEDs). BACKGROUND Early, definite recognition of CIED-related infections combined with accurate localization and quantification of disease burden is a prerequisite for optimal treatment strategies. METHODS All 63 consecutive patients underwent clinical examination, blood chemistry, microbiology, and echography of the cardiac region/venous pathway of the device. Final diagnosis of infection was established in 32 of 63 patients and in 23 of 32 by microbiology. RESULTS Sensitivity of Tc-99m-HMPAO-WBC single-photon emission computed tomography/computed tomography (SPECT/CT) was 94% for both detection and localization of CIED-associated infection. SPECT/CT imaging had a definite added diagnostic value over both planar and stand-alone SPECT. Pocket infection was often associated with lead(s) involvement; the intracardiac portion of the lead(s) more frequently exhibited Tc-99m-HMPAO-WBC accumulation and presented the highest rate of complications, infectious endocarditis, and septic embolism. Two false negative cases and no false positive results were observed. None of the patients with negative Tc-99m-HMPAO-WBC scintigraphy developed CIED-related infection during follow-up of 12 months. Echography of the cardiac region/venous pathway of the device had 90% specificity, but low sensitivity (81% when intracardiac lead[s] infection only was considered). The Duke criteria had 31% sensitivity for the definite category (100% specificity) and 81% for the definite and possible categories (77% specificity). CONCLUSIONS Tc-99m-HMPAO-WBC scintigraphy enabled the confirmation of the presence of CIED-associated infection, definition of the extent of device involvement, and detection of associated complications. Moreover, Tc-99m-HMPAO-WBC scintigraphy reliably excluded device-associated infection during a febrile episode and sepsis, with 95% negative predictive value. (C) 2013 by the American College of Cardiology Foundation
DOI
10.1016/j.jcmg.2013.08.001
WOS
WOS:000326205300007
Archivio
http://hdl.handle.net/11390/1198946
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84886055142
Diritti
metadata only access
Scopus© citazioni
99
La settimana scorsa
2
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
114
Data di acquisizione
Mar 25, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback