A retrospective study of endobronchial ultrasound transbronchial needle aspiration versus conventional transbronchial needle aspiration in diagnosis/staging of hilar/mediastinal lymph node in lung cancer: Which role in clinical practice?

Conte, Sergio C.
•
Spagnol, Giulia
•
Biolo, Marco
•
Confalonieri, Marco
2019
  • journal article

Periodico
MONALDI ARCHIVES FOR CHEST DISEASE
Abstract
The conventional-trans bronchial needle aspiration (c-TBNA) has been the first procedure for sampling hilar/mediastinal lymph node for the diagnosis/staging of lung cancer. In the last decade the endobronchial ultrasound trans bronchial needle aspiration (EBUS-TBNA) was introduced in clinical practice and became the first-choice exam in diagnosis and staging of lung cancer. The aim of this study was to compare the diagnostic accuracy (DA), sensitivity and adequacy of c-TBNA and EBUS-TBNA. It was a retrospective and observational multicenter study. The first endpoint was diagnostic accuracy of EBUS-TBNA versus c-TBNA. The secondary end-points were sensitivity and adequacy. Two hundred and nine consecutive patients underwent the procedure, 99 EBUS-TBNA and 110 c-TBNA. When lymph nodes with short axis <2 cm the diagnostic accuracy for correct diagnosis was 94.2% in EBUS-TBNA group and 89.7% in c-TBNA group (p=0.01); the sample adequacy was 70.3% and 42%, respectively (p=0.01); the sensitivity was 93% (95% CI, 82-98%) and 86.4% (95% CI, 67.6-95.6%), respectively (p=0.002). In lymph nodes with short axis ≥2 cm the diagnostic accuracy was 95.7% in EBUS-TBNA group and 93% in c-TBNA group (p=0.939); the sample adequacy was 68.7% and 68.3%, respectively (p=0.889); the sensitivity was 95.1% (95% CI, 83-99%) and 92.1%, respectively (95% CI, 78.7-97.7%) (p=0.898). The EBUS-TBNA in patients with lymph nodes size <2 cm presented a statistically significant difference in the DA, adequacy and sensitivity compared to c-TBNA procedure, while there were no significant differences in the DA, adequacy and sensitivity between EBUS-TBNA and c-TBNA in patients with lymph node size ≥2 cm. The results of our study indicated that the EBUS-TBNA should be the first-choice procedure for the diagnosis/staging in lung cancer patients with lymph node size <2 cm. In patients with lymph node size ≥2 cm, instead, both procedures can be used for the diagnosis/staging of lung cancer.
DOI
10.4081/monaldi.2019.1010
WOS
WOS:000468399900005
Archivio
http://hdl.handle.net/11368/2943405
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85064569990
https://www.monaldi-archives.org/index.php/macd/article/view/1010
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by-nc/4.0/
FVG url
https://arts.units.it/bitstream/11368/2943405/1/2019 Monaldi Conte Confalonieri.pdf
Soggetti
  • Conventional transbro...

  • Diagnostic accuracy

  • Endobronchial ultraso...

  • Lymphadenopathy

  • Sensitivity

  • Pulmonary and Respira...

Scopus© citazioni
1
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
3
Data di acquisizione
Mar 27, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback