Logo del repository
  1. Home
 
Opzioni

A framework for iterative reconstruction in phase-contrast computed tomography dedicated to the breast

Sarno, A.
•
Golosio, B.
•
Russo, P.
altro
Tromba, G.
2017
  • journal article

Periodico
IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES
Abstract
We present the implementation of the CT iterative reconstruction strategy developed within the SYRMA-CT project for in vivo phase contrast CT of the uncompressed breast, ongoing at the ELETTRA synchrotron radiation facility (Trieste, Italy). Propagation-based phase-contrast imaging exploited the high spatial coherence of the monoenergetic laminar X-ray beam (3-mm high along the chest-wall-to-nipple direction), as well as the large object-to-detector distance (∼2 m) and the use of a prototype of Pixirad-8 high-resolution photon counting CdTe detector (60-μm pitch, eight detector units arranged in a row). The signal in projection views depends on the X-ray absorption as well as on the phase shift introduced by the breast tissue in the beam path. A phase retrieval algorithm allows recovering the projected 2D phase map of the irradiated tissue layer, which were input to the CT reconstruction; then, the 3D image of the breast was reconstructed via a simultaneous algebraic reconstruction technique (SART) algorithm. The developed iterative reconstruction - coupled with a filtering process for reducing the noise level and ring artifacts by preserving edges sharpness - showed better image quality than conventional filtered backprojection (FBP) reconstruction. A phantom study showed that the iterative reconstruction produced images with a contrast-to-noise-ratio up to 65% and a spatial resolution up to 12% higher than those obtained with FBP. Finally, the developed algorithm removed ring-like artifacts caused by the detector dead space (0.16 mm) across adjacent detector units and by no perfect equalization after flat-field correction, without worsening the image quality.
DOI
10.1109/TRPMS.2017.2749059
WOS
WOS:000456147300004
Archivio
http://hdl.handle.net/11368/2917161
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85041546116
http://ieeexplore.ieee.org/document/8026123/
Diritti
closed access
license:copyright editore
FVG url
https://arts.units.it/request-item?handle=11368/2917161
Soggetti
  • Radiology

  • Instrumentation

  • tomography

Scopus© citazioni
2
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
5
Data di acquisizione
Mar 22, 2024
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback