Abstract
Purpose: To assess the effectiveness of a one-step and a two-step system with diamond pastes for polishing packable and flowable nanofilled resin composites. Methods and materials: Thirty discs per material tested, a packable (Filtek Supreme XT, 3M ESPE) and a flowable nanofilled resin composite (Filtek Supreme XT Flow, 3M ESPE), were prepared pouring the materials into silicon molds (depth 2 mm, diameter 4 mm). The top surface of the specimens was covered with a Mylar strip and light-cured with a halogen lamp at 600 mW/cm2 for 60 s. Ten specimens of each material did not undergo polishing and were used as controls. Spec- imens to be polished were finished with 1200P sandpaper and assigned to two polishing protocols: one-step diamond paste (Unigloss, Intensive) (n = 10) and two-step diamond paste (Diamond Polishing Mint, Ultradent Products) (n=10). A lin- ear rugosimetric parameter (Ra) was measured three times on randomly selected areas of the top surface of all specimens. The arithmetic mean of the readings was calculated and con- stituted the statistical unit. Data were subjected to statistical analysis with Kruskal–Wallis and Mann–Whitney tests with Bonferroni correction (p<0.05). The morphology of top sur- faces of representative polished specimens was assessed by scanning electron microscopy. Results: Both control and experimental groups never exceeded the 0.20-μm Ra threshold that can inhibit bacterial adhesion. The mean surface roughness and standard devia- tion of polished specimens were: packable/one-step system, 0.058 ± 0.006 μm; packable/two-step system, 0.048 ± 0.005 μm; flowable/one-step system 0.044 ± 0.006 μm; flowable/two-step system 0.049±0.006μm. The surface of the packable com- posite polished with the one-step system was significantly rougher than its Mylar control (p < 0.01) and flowable compos- ite polished with the same protocol (p < 0.05). Observation by scanning electron microscopy did not detect relevant surface irregularities. The surface of polished specimens appeared similarly smooth regardless of composite type or polishing system. Conclusion: Both tested systems effectively polished both the flowable and packable nanofilled composites. A two-step system appears preferable for polishing the packable com- posite. The resin Filtek Supreme XT Flow can be efficiently polished with the one-step system.
DOI
10.1016/j.dental.2014.08.155
Archivio
http://hdl.handle.net/11368/2830490
Diritti
metadata only access
Soggetti
  • Surface roughness, Na...

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback