The impact of different calibration matrices on the determination of insulin-like growth factor 1 by high-resolution-LC-MS in acromegalic and growth hormone deficient patients

Simstich S.
•
Zullig T.
•
D'Aurizio F.
altro
Herrmann M.
2023
  • journal article

Periodico
CLINICAL BIOCHEMISTRY
Abstract
Objectives: Calibration is an important source of variability in liquid chromatography mass spectrometry (LC-MS) methods for insulin-like growth factor 1 (IGF-1). This study investigated the impact of different calibrator matrices on IGF-1 measurements by LC-MS. Moreover, the comparability of immunoassays and LC-MS was assessed. Design & Methods: Calibrators from 12.5 to 2009 ng/ml were prepared by spiking WHO international Standard (ID 02/254 NIBSC, UK) into the following matrices: native human plasma, fresh charcoal-treated human plasma (FCTHP), old charcoal-treated human plasma, deionized water, bovine serum albumin (BSA), and rat plasma (RP). A validated in-house LC-MS method was calibrated repeatedly with these calibrators. Then, serum samples from 197 growth hormone excess and deficiency patients were analysed with each calibration. Results: The seven calibration curves had different slopes leading to markedly different patient results. The largest differences in IGF-1 concentration from the median (interquartile range) was observed with the calibrator in water and the calibrator in RP (336.4 [279.6–417.0] vs. 112.5 [71.2–171.2], p < 0.001). The smallest difference was observed with calibrators in FCTHP and BSA (141.8 [102.0–198.5] vs. 127.9 [86.9–186.0], p < 0.049). Compared to LC-MS with calibrators in FCTHP, immunoassays showed relevant proportional bias (range: −43% to −68%), constant bias (range: 22.84 to 57.29 ng/ml) and pronounced scatter. Comparing the immunoassays with each other revealed proportional bias of up to 24%. Conclusions: The calibrator matrix is critical for the measurement of IGF-1 by LC-MS. Regardless of the calibrator matrix, LC-MS shows poor agreement with immunoassays. Also, the agreement between different immunoassays is variable.
DOI
10.1016/j.clinbiochem.2023.02.008
Archivio
https://hdl.handle.net/11390/1243358
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85149321104
https://ricerca.unityfvg.it/handle/11390/1243358
Diritti
open access
Soggetti
  • Hormone

  • Insulin-like Growth F...

  • Liquid Chromatography...

  • Online Solid Phase Ex...

  • Peptide

  • Quantification

  • Serum

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback