Logo del repository
  1. Home
 
Opzioni

A novel 1-L PEG + ascorbate versus high-volume PEG regimen for colonoscopy cleansing: a multicenter, randomized, phase IV study

Repici A
•
Spada C
•
Cannizzaro R
altro
Hassan C
2021
  • journal article

Periodico
GASTROINTESTINAL ENDOSCOPY
Abstract
Background and aims: Adequate bowel cleansing is critical to ensure quality and safety of a colonoscopy. A novel 1-L polyethylene glycol plus ascorbate (1L-PEG+ASC) regimen was previously validated against low-volume regimens but was never compared with high-volume regimens. Methods: In a phase IV study, patients undergoing colonoscopy were randomized 1:1 to receive split-dose 1L PEG+ASC or a split-dose 4-L PEG-based regimen (4L-PEG) in 5 Italian centers. Preparation was assessed with the Boston Bowel Preparation Scale (BBPS) by local endoscopists and centralized reading, both blinded to the randomization arm. The primary endpoint was noninferiority of 1L-PEG+ASC in colon cleansing. Secondary endpoints were superiority of 1L-PEG+ASC, patient compliance, segmental colon cleansing, adenoma detection rate, tolerability, and safety. Results: Three hundred eighty-eight patients (median age, 59.8 years) were randomized between January 2019 and October 2019: 195 to 1L-PEG+ASC and 193 to 4L-PEG. Noninferiority of 1L-PEG+ASC was demonstrated for cleansing in both the entire colon (BBPS ≥ 6: 97.9% vs 93%; relative risk [RR], 1.03; 95% confidence interval [CI], 1.001-1.04; P superiority = .027) and in the right-sided colon segment (98.4% vs 96.0%; RR, 1.02; 95% CI, .99-1.02; P noninferiority = .013). Compliance was higher with 1L-PEG+ASC than with 4L-PEG (178/192 [92.7%] vs 154/190 patients [81.1%]; RR, 1.10; 95% CI, 1.05-1.12), whereas no difference was found regarding safety (moderate/severe side effects: 20.8% vs 25.8%; P = .253). No difference in adenoma detection rate (38.8% vs 43.0%) was found. Conclusions: One-liter PEG+ASC showed noninferiority compared with 4L-PEG in achieving adequate colon cleansing and provided a higher patient compliance. No differences in tolerability and safety were detected. (Clinical trial registration number: NCT03742232.).
DOI
10.1016/j.gie.2021.04.020
WOS
WOS:000695807200019
Archivio
https://hdl.handle.net/11368/3056318
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85113640741
https://www.sciencedirect.com/science/article/pii/S0016510721013183?via=ihub
Diritti
open access
license:copyright editore
license:creative commons
license uri:iris.pri02
license uri:http://creativecommons.org/licenses/by-nc-nd/4.0/
FVG url
https://arts.units.it/request-item?handle=11368/3056318
Soggetti
  • colonoscopy

  • PEG

  • laxatines

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback