Reliability of an injection-moulded two-piece zirconia implant with PEKK abutment after long-term thermo-mechanical loading

Zhang F
•
Meyer zur Heide
•
Chevalier, J
altro
Spies, B.
2020
  • journal article

Periodico
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS
Abstract
Zirconia implants are appreciated in some clinical indications in light of their aesthetic appearance and good biocompatibility. The aim of this work was to evaluate the performance of a newly developed two-piece zirconia/polyether ketone ketone (PEKK) implant-abutment combination after long-term cyclic loading in a hydrothermal environment, using a new protocol adapted from two available ISO standards. Sixteen implants (n = 8/group) were embedded according to ISO 14801 and divided into two groups: implants in the Observational Group (OG) were cyclically loaded for 60 days (98 N, 10 million loading cycles, 2 Hz) in 85 °C water in a chewing simulator, while non-loaded/non-aged implants (as-received) constituted the Control Group (CG). After 4.7 million loading cycles, one OG implant fractured in the chewing simulator. The surviving implants were compared to CG implants by X-ray diffraction (XRD) to investigate potential ageing as suggested by ISO 13356, but also μ-Raman spectroscopy, Focused-Ion-Beam - Scanning-Electron-Microscopy (FIB-SEM), and load-to-fracture. Ageing was shown to have limited influence on the evaluated zirconia implant, with increased monoclinic content after loading/ageing being to a shallow transformed zone of ~2 μm at the implant surface. However, OG implants showed a significantly decreased fracture load of 751 ± 231 N (CG: 995 ± 161 N; p =.046). These values enable clinical application, but the fact that one failure was recorded during cyclic fatigue along with the significant decrease in strength after cyclic loading/ageing suggest that there may be room for further optimization of especially the PEKK abutment. Furthermore, good agreement was observed between the fracture modes of the implant that failed during the cyclic fatigue experiment and the in vivo failure of one implant during pre-clinical trials, validating the interest of the in vitro protocol used in this work to check the reliability of zirconia implant.
DOI
10.1016/j.jmbbm.2020.103967
WOS
WOS:000569170800003
Archivio
http://hdl.handle.net/11368/2969975
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85088219240
https://www.sciencedirect.com/science/article/pii/S1751616120305208
Diritti
open access
license:creative commons
license:copyright editore
license uri:http://creativecommons.org/licenses/by-nc-nd/4.0/
FVG url
https://arts.units.it/request-item?handle=11368/2969975
Soggetti
  • Ageing

  • Fatigue

  • PEKK

  • Two-piece implant

  • Zirconia

Web of Science© citazioni
10
Data di acquisizione
Mar 26, 2024
Visualizzazioni
6
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback