Logo del repository
  1. Home
 
Opzioni

Surface modifications induced by in-vitro wear and oxidation on γ-irradiated UHMWPE hip liners belonging to different commercial generations

Leonardo, Puppulin
•
DELLA NEGRA, SARA
•
Nobuhiko, Sugano
altro
Giuseppe, Pezzotti
2016
  • journal article

Periodico
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS
Abstract
Single-step and three-step irradiated and annealed ultra-high molecular weight polyethylene (UHMWPE) hip liners have been studied by means of Raman spectroscopy (RS) and Fourier transform infrared spectroscopy (FT-IR), in order to clarify the microstructural modifications induced by in vitro oxidative degradation and wear. These spectroscopic techniques enabled us to measure profiles of oxidation index (OI), crystalline (αc), amorphous (αa), and third phase (αb) fractions along the subsurface of the acetabular cups as a function of in vitro oxidation time or after standard testing in hip simulator. Microtomed sections of the liners after accelerated aging (ASTM F2003-02) showed that oxidation profiles developed differently during the first two weeks, while all samples aged longer than 2 weeks revealed OI increasing with lower rates. The initial oxidation of the single-step-annealed material was higher than the one retrieved from the 3-step-annealed material and showed a peak of OI located at a depth of ~1 mm below the exposed surface. The profiles of αc, calculated from the same sample cross-sections, followed trends similar to the respective OI profiles, which enabled a phenomenological (but quantitative) correlation between oxidation and crystallization processes to be obtained. Wear simulation under edge loading conditions was conducted on series of four samples of the above two types of irradiated and annealed materials, and for two different liner thicknesses (5.9 and 7.9 mm). The wear rates calculated at the end of the test were very low for all samples (max 2.08 mm3/mc for the thinner liners of the single-step irradiated and annealed material). The results indicated that there was a statistically significant increase in both wear rate and volume loss only for the thinner single-step irradiated and annealed liners. Surface analyses by Raman spectroscopy revealed distinct gradients of crystallinity, amorphous, and third phase fractions along the in-depth axis. In both types of UHMWPE materials, the worn area showed an increase of crystallinity at the expense of the third phase. Differences in crystallinity profiles observed at the wear zone of liners with different thicknesses were correlated to the higher contact stress experienced by thinner liners.
DOI
10.1016/j.jmbbm.2015.08.035
WOS
WOS:000366226500038
Archivio
http://hdl.handle.net/11368/2911830
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84942275017
http://www.sciencedirect.com/science/article/pii/S1751616115003197?via%3Dihub
Diritti
closed access
license:digital rights management non definito
FVG url
https://arts.units.it/request-item?handle=11368/2911830
Soggetti
  • UHMWPE

  • Hip replacement

  • Raman spectroscopy

  • FT-IR

  • Oxidation

  • Wear.

Scopus© citazioni
7
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
8
Data di acquisizione
Mar 12, 2024
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback