Logo del repository
  1. Home
 
Opzioni

End-tidal versus manually-controlled low-flow anaesthesia

LUCANGELO, UMBERTO
•
Giuliana Garufi
•
Emanuele Marras
altro
Walter A. Zin
2013
  • journal article

Periodico
JOURNAL OF CLINICAL MONITORING AND COMPUTING
Abstract
During low-flow manually-controlled anaesthesia (MCA) the anaesthetist needs constantly adjust end-tidal oxygen (EtO2) and anaesthetic concentrations (EtAA) to assure an adequate and safe anaesthesia. Recently introduced anaesthetic machines can automatically maintain those variables at target values, avoiding the burden on the anaesthetist. End-tidal-controlled anaesthesia (EtCA) and MCA provided by the same anaesthetic machine under the same fresh gas flow were compared. Eighty patients were prospectively observed: in MCA group (n = 40) target end-tidal sevoflurane (1 %) and EtO2 concentrations (≥35 %) were manually controlled by the anaesthetist. In EtCA group (n = 40) the same anaesthetic machine with an additional end-tidal control feature was used to reach the same targets, rendering automatic the achievement and maintenance of those targets. Anaesthetic machine characteristics, amount of consumed gases, oxygen and sevoflurane efficiencies, and the amount of interventions by the anaesthetist were recorded. In EtCA group EtAA was achieved later (145 s) than in MCA (71 s) and remained controlled thereafter. Even though the target expired gas fractions were achieved faster in MCA, manual adjustments were required throughout anaesthesia for both oxygen and sevoflurane. In MCA patients the number of manual adjustments to stabilize EtAA and EtO2 were 137 and 107, respectively; no adjustment was required in EtCA. Low-flow anaesthesia delivered with an anaesthetic machine able to automatically control EtAA and EtO2 provided the same clinical stability and avoided the continuous manual adjustment of delivered sevoflurane and oxygen concentrations. Hence, the anaesthetist could dedicate more time to the patient and operating room activities
DOI
10.1007/s10877-013-9516-8
WOS
WOS:000332800200003
Archivio
http://hdl.handle.net/11368/2765520
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84897023703
Diritti
metadata only access
Soggetti
  • anaesthesia

Web of Science© citazioni
19
Data di acquisizione
Mar 23, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback