Polymerization kinetics of dental adhesives cured with LED: correlation between extent of conversion and permeability.

BRESCHI L
•
CADENARO, MILENA
•
ANTONIOLLI F
altro
DI LENARDA, Roberto
2007
  • journal article

Periodico
DENTAL MATERIALS
Abstract
OBJECTIVES: The aim of this study was to analyze the polymerization kinetics of different adhesive films in relation to their permeability after exposure to different LED curing units. METHODS: One adhesive from each class was analyzed: a three-step etch-and-rinse (OptiBond FL; Sybron-Kerr), a two-step etch-and-rinse (One-Step, Bisco), a two-step self-etch (Clearfil Protect Bond, Kuraray) and a one-step self-etch adhesive (Xeno III; Dentsply DeTrey). Adhesive films were prepared and cured with SmartLite IQ (Dentsply) or L.E. Demetron I (Demetron Kerr) up to complete curing. Polymerization kinetic curves of the tested adhesives were obtained with differential scanning calorimetry (DSC). In particular, total reaction time and extent of polymerization (Ep) at 20, 40 or 60s were compared. Permeability of the adhesive films was evaluated on flat dentin surfaces of human extracted teeth connected to a permeability device and statistically analyzed. RESULTS: Total reaction time differed among the adhesives tested: OptiBond FL<Clearfil Protect Bond<One-Step<Xeno III with both curing units (p<0.05). At 20s OptiBond FL showed the highest Ep, while the lowest values were obtained with One-Step and Xeno III (p<0.05). E(p) increased when curing time was prolonged (40 and 60s) for all adhesives tested (p<0.05), however, on simplified adhesives, incomplete polymerization took place even after prolonged exposure intervals. An inverse correlation was found between Ep of the adhesives and their permeability using LED curing units. SIGNIFICANCE: This study supports the hypothesis that, longer curing times than those recommended by the respective manufacturer decrease permeability of the bonded interfaces.
DOI
10.1016/j.dental.2006.06.040
WOS
WOS:000249085700003
SCOPUS
2-s2.0-34547122878
Archivio
http://hdl.handle.net/11368/1691392
http://www.ncbi.nlm.nih.gov/pubmed/?term=Polymerization+kinetics+of+dental+adhesives+cured+with+LED%3A+correlation+between+extent+of+conversion+and+permeability.
Diritti
metadata only access
Soggetti
  • dental adhesives

  • extent of polymerizat...

  • permeability

  • dentin

  • LED curing units

Web of Science© citazioni
72
Data di acquisizione
Mar 25, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback