Logo del repository
  1. Home
 
Opzioni

Comparison of Nicotinic Acid- and caloric restriction-induced hyperbilirubinaemia in the diagnosis of Gilbert’s syndrome

Gentile, S
•
Orzes, N
•
Persico, M
altro
TIRIBELLI, CLAUDIO
1985
  • journal article

Periodico
JOURNAL OF HEPATOLOGY
Abstract
The diagnostic value of the nicotinic acid (NA)-induced hyperbilirubinaemia was compared with that resulting from caloric restriction in 40 patients with Gilbert's syndrome (GS) and 20 controls. Both tests resulted in a significant higher level of serum bilirubin in GS than in controls (P less than 0.001). When the serum bilirubin level 240 min after NA administration (5.9 mumol/kg i.v.) was higher than 18 mumoles/l, this test had a specificity and sensitivity of 100%, both in males and females with the syndrome. The discriminatory value of the test was lower when either the area under the time concentration curve or the maximal increment of serum unconjugated bilirubin were used. Reduction in caloric intake (400 calories/day) showed a lower specificity and sensitivity than the NA test, particularly in females. An increment of bilirubin at 24 h greater than 15 mumoles/l was more diagnostic than an increase by 100% or more over the pre-diet value. The efficacy was not improved by prolonging the test for additional 24 h. From these data we conclude that NA-induced hyperbilirubinaemia and, in particular the concentration of the pigment 240 min after drug administration, is more efficient than fasting-induced hyperbilirubinaemia in the diagnosis of the Gilbert's syndrome both in males and in females.
Archivio
http://hdl.handle.net/11368/2844263
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-0021813872
http://www.ncbi.nlm.nih.gov/pubmed/4056354
Diritti
metadata only access
Soggetti
  • Energy Intake* Femal...

Scopus© citazioni
16
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Visualizzazioni
4
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback