Logo del repository
  1. Home
 
Opzioni

Lupus anticoagulant: A multicenter study for a standardized and harmonized reporting

POZ, Alessandra
•
GIACOMELLO, Roberta
•
Pradella, Paola
altro
Zardo, Lorena
2016
  • journal article

Periodico
BLOOD COAGULATION & FIBRINOLYSIS
Abstract
Laboratory assessment of Lupus anticoagulant (LAC) is very challenging because of inter and intralaboratory variability, which makes it difficult to standardize and harmonize results expression. Five hospital laboratories in North-eastern Italy shared their efforts and their experience in a cross-laboratory study, conducting the diagnostic process as homogeneously as possible and providing a better interpretation for LAC positivity. Hundred normal samples from healthy subjects (20 from each center) were processed to confirm negative upper limits and calculate positivity cutoffs of LAC integrated assays, that is dilute Russell's viper venom time (dRVVT) and silica clotting time (SCT). Moreover, 311 samples previously diagnosed by the laboratories as positive for LAC were analyzed to characterize different positivity levels for each assay. As far as the analysis of healthy subjects is concerned, negative upper limits are set at 1.17 and 1.19 for dRVVT and SCT screen ratio, respectively. Positivity cutoffs are set at 1.20 for dRVVT and 1.23 for SCT, expressed as Test Ratio calculated on screen and confirm integrated tests. Positive results for each integrated assay are subsequently divided into three subgroups: weak, moderate and strong; the results obtained are presented as a score proposal that can provide LAC interpretation. The combined use of both dRVVT and SCT assays and the definition of different positivity levels may lead to clearer, more objective LAC reporting. An interpretative table for LAC-proposed score provides LAC-positive results and it is now adopted by all centers involved in the study.
DOI
10.1097/MBC.0000000000000414
WOS
WOS:000369548400013
Archivio
http://hdl.handle.net/11390/1110789
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84957438391
http://journals.lww.com/bloodcoagulation/pages/default.aspx
Diritti
metadata only access
Soggetti
  • harmonization

  • Lupus anticoagulant

  • multicenter study

  • reporting

  • scoring system

  • standardization

  • Antiphospholipid Synd...

  • Biological Assay

  • Biomarker

  • Case-Control Studie

  • Human

  • Laboratory Proficienc...

  • Lupus Coagulation Inh...

  • Reference Value

  • Reproducibility of Re...

  • Research Design

  • Sensitivity and Speci...

  • Hematology

Scopus© citazioni
5
Data di acquisizione
Jun 2, 2022
Vedi dettagli
Web of Science© citazioni
6
Data di acquisizione
Mar 22, 2024
Visualizzazioni
3
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback