Diagnostic accuracy of 16-row multislice CT angiography in the evaluation of coronary segments

Cademartiri F.
•
Runza G.
•
Marano R.
altro
BELGRANO, MANUEL GIANVALERIO
2005
  • journal article

Periodico
LA RADIOLOGIA MEDICA
Abstract
PURPOSE: To evaluate the diagnostic accuracy of 16-row multislice spiral computed tomography coronary angiography (16-MSCT-CA) for the non-invasive assessment of significant coronary artery stenosis. MATERIALS AND METHODS: We enrolled 40 patients (36 male, aged 59+/-11 yrs) with suspected obstructive coronary artery disease and a heart rate <65 bpm during the scan. The 16-MSCT-CA (Sensation 16, Siemens, Forchheim, Germany) was performed with electrocardiographically-gated technique after the intravenous administration of 100 ml of iodinated contrast material followed by a saline bolus chaser. The scan parameters were: collimation 16 x 0.75 mm, rotation time 0.42 s, feed/rot. 3 mm (pitch 0.25), 120 kVp, 500 mAs. All coronary segments = or >2 mm in diameter were evaluated by two independent observers for the presence of significant coronary artery stenosis (= or >50%). Consensus reading was compared to quantitative coronary angiography. RESULTS: The average heart rate was 55+/-6 bpm. Of the 428 segments of = or >2.0 mm diameter 92 were significantly diseased. Without exclusion of any branches (428), the sensitivity, specificity, positive, and negative predictive values to identify = or >50% obstructed segments were 95.7% (88/92), 95.8% (322/336), 86.3% (88/102), and 98.8% (322/326), respectively. No occluded left main, left anterior descending, circumflex or right coronary artery segments remained undetected. CONCLUSIONS: 16-MSCT-CA in a selected low-heart-rate patient population provides high diagnostic accuracy in the evaluation of significant coronary artery stenosis.
Archivio
http://hdl.handle.net/11368/2297798
Diritti
metadata only access
Soggetti
  • Contrast Media *Coron...

  • Spiral Computed

Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback