Logo del repository
  1. Home
 
Opzioni

Quality of images with toric intraocular lenses

Tognetto, Daniele
•
PERROTTA, ALBERTO ARMANDO
•
BAUCI, FRANCESCO
altro
Alpins, Noel
2018
  • journal article

Periodico
JOURNAL OF CATARACT AND REFRACTIVE SURGERY
Abstract
Purpose: To objectively evaluate the image quality obtained with toric intraocular lenses (IOLs) when misaligned from the intended axis. Setting: University Eye Clinic and the Department of Industrial and Information Engineering, University of Trieste, Trieste, Italy. Design: Experimental study. Methods: An experimental optoelectronic test bench was created. It consisted of a high-resolution monitor to project target images and an artificial eye. The system simulates the optical and geometric characteristics of the human eye with an implanted toric IOL. A 3.00 diopters corneal astigmatism was simulated. Images reproduced by the optical system were captured according to different IOL axis positions. The quality of each image was analyzed using the visual information fidelity (VIF) criterion. The VIF reduction was calculated at each IOL rotational step. Results: A 5-degree IOL axis rotation from the intended position determined a decay in the image quality of 7.03%. Ten degrees of IOL rotation caused an 11.09% decay of relative VIF value. For a 30-degree rotation, the VIF decay value was 45.85%. Finally, the image decay with no toric correction was 56.70%. Conclusions: The more the objective quality of the image decays progressively, the further the axis of the IOL is rotated from its intended position. The reduction in image quality obtained after 30 degrees of toric IOL rotation was less than 50% and after 45 degrees, the image quality was the same as that of no toric correction.
DOI
10.1016/j.jcrs.2017.10.053
WOS
WOS:000431607000019
Archivio
http://hdl.handle.net/11368/2926040
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85046115126
https://journals.lww.com/jcrs/Abstract/2018/03000/Quality_of_images_with_toric_intraocular_lenses.19.aspx
Diritti
open access
FVG url
https://arts.units.it/request-item?handle=11368/2926040
Soggetti
  • Surgery

  • Ophthalmology

  • Sensory Systems

Scopus© citazioni
18
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
26
Data di acquisizione
Mar 20, 2024
Visualizzazioni
4
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback