Effect of particle aspect ratio in targeted drug delivery in abdominal aortic aneurysm

Salavatidezfouli, Sajad
•
Barzegar, Saeid
•
Sheidani, Armin
altro
Rozza, Gianluigi
2024
  • journal article

Periodico
EUROPEAN JOURNAL OF MECHANICS. B, FLUIDS
Abstract
Aneurysm is a permanent irreversible bulge in the artery that can occur with higher prevalence among elderly individuals. Although invasive surgical procedures can prevent their development, they come with considerable side effects. Recently, treatments based on targeted drug delivery have gained a lot of attention to suppress aneurysm growth. Numerical simulations have been shown to be of great role in the prediction of blood hemodynamics and vascular wall behaviour in the case of an aneurysm. Moreover, the utilization of high-fidelity approaches such as the Lagrangian frame of reference can address the motion characteristics of microbubble (MB) contrast agents in particulate flows. This study aims to investigate the effect of particle aspect ratio on the adhesion of oblate spheroid particles to the vascular wall. Accordingly, a two-way fluid–structure interaction (FSI) method consisting of a hyperelastic material model for the vessel along with a non-Newtonian, compressible model for blood was employed to simulate an abdominal aortic aneurysm (AAA). Moreover, the ligand–receptor binding concept has been utilized to address the quantification of MBs adhesion. Five sets of aspect ratios ranging from 1 to 9 have been investigated and results indicated that with the increase of the aspect ratio the rate of adhesion decreases. Two drastic changes in the particle number occurred due to the diastolic peak and negative velocity profile, respectively. However, it was concluded that the hydrodynamic of the MBs in terms of velocity and wall distance is rather insensible to the particle shape.
DOI
10.1016/j.euromechflu.2024.04.009
WOS
WOS:001239841000001
Archivio
https://hdl.handle.net/20.500.11767/145354
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85192178918
https://ricerca.unityfvg.it/handle/20.500.11767/145354
Diritti
metadata only access
Soggetti
  • Abdominal aortic aneu...

  • Discrete element meth...

  • Drug delivery

  • Fluid–structure inter...

  • Non-spherical

  • Settore MATH-05/A - A...

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback