Logo del repository
  1. Home
 
Opzioni

Global Variation in Magnetic Resonance Imaging Quality of the Prostate

Giganti, Francesco
•
Ng, Alexander
•
Asif, Aqua
altro
PRIME Quality Improvement Group 1
2023
  • journal article

Periodico
RADIOLOGY
Abstract
: Background High variability in prostate MRI quality might reduce accuracy in prostate cancer detection. Purpose To prospectively evaluate the quality of MRI scanners taking part in the quality control phase of the global PRIME (Prostate Imaging Using MRI ± Contrast Enhancement) trial using the Prostate Imaging Quality (PI-QUAL) standardized scoring system, give recommendations on how to improve the MRI protocols, and establish whether MRI quality could be improved by these recommendations. Materials and Methods In the prospective clinical trial (PRIME), for each scanner, centers performing prostate MRI submitted five consecutive studies and the MRI protocols (phase I). Submitted data were evaluated in consensus by two expert genitourinary radiologists using the PI-QUAL scoring system that evaluates MRI diagnostic quality using five points (1 and 2 = nondiagnostic; 3 = sufficient; 4 = adequate, 5 = optimal) between September 2021 and August 2022. Feedback was provided for scanners not achieving a PI-QUAL 5 score, and centers were invited to resubmit new imaging data using the modified protocol (phase II). Descriptive comparison of outcomes was made between the MRI scanners, feedback provided, and overall PI-QUAL scores. Results In phase I, 41 centers from 18 countries submitted a total of 355 multiparametric MRI studies from 71 scanners, with nine (13%) scanners achieving a PI-QUAL score of 3, 39 (55%) achieving a score of 4, and 23 (32%) achieving a score of 5. Of the 48 (n = 71 [68%]) scanners that received feedback to improve, the dynamic contrast-enhanced sequences were those that least adhered to the Prostate Imaging Reporting and Data System, version 2.1, criteria (44 of 48 [92%]), followed by diffusion-weighted imaging (20 of 48 [42%]) and T2-weighted imaging (19 of 48 [40%]). In phase II, 36 centers from 17 countries resubmitted revised studies, resulting in a total of 62 (n = 64 [97%]) scanners with a final PI-QUAL score of 5. Conclusion Substantial variation in global prostate MRI acquisition parameters as a measure of quality was observed, particularly with DCE sequences. Basic evaluation and modifications to MRI protocols using PI-QUAL can lead to substantial improvements in quality. Clinical trial registration no. NCT04571840 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Almansour and Chernyak in this issue.
DOI
10.1148/radiol.231130
Archivio
https://hdl.handle.net/11390/1271106
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85173316015
https://ricerca.unityfvg.it/handle/11390/1271106
Diritti
metadata only access
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback