Logo del repository
  1. Home
 
Opzioni

Confirmation of correct central venous catheter position in the preoperative setting by echocardiographic "bubble-test"

Meggiolaro, M.
•
Scatto, A.
•
Zorzi, A.
altro
Bonaccorso, G.
2015
  • journal article

Periodico
MINERVA MEDICA
Abstract
Abstract Background. Verification of the central venous catheters (CVCs) position by chest X-ray (CXR) is usually performed in the postoperative period with the risk related to possible malposition. This prospective observational study aimed to assess the diagnostic accuracy and reproducibility of ultrasound (US) and "bubble test" to detect malpositions of CVC in the preoperative setting. Methods. The study included 105 patients undergoing preoperative CVC placement. A US protocol aimed at direct visualization of the CVC was completed by a single operator and two consecutive "bubble tests" were performed independently by different physicians. Two parameters were considered: complete right atrium (RA) opacization versus visualization of "no or few bubbles" and time from agitated saline injection to visualization of micro-bubbles in the RA ("push-to-bubbles" time). Results. CXR identified 14 (13%) CVC malpositions. Vascular US showed a sensitivity of 64% and a specificity of 100% while visualization of "no or few bubbles" at bubble test yielded a sensitivity of 50% and a specificity of 100%. "Push-to-bubbles" times were approximate to 9 times longer in patients with compared to those without CVC malposition (1400 [702-2160] ms versus 167 [123-228] ms, P<0.001). A cut off value of 500 ms had a sensitivity of 100% and a specificity of 99% for CVC malposition with an inter-observer agreement of 99% (kappa 0.96, P<0.001). Conclusion. CVC malposition was observed in a sizeable proportion of patients undergoing preoperative central venous cannulation. Measurement of "push-to-bubbles" time is a fast, accurate and highly reproducible tool for verifying the correct CVC position.
WOS
WOS:000363913700009
Archivio
http://hdl.handle.net/11368/3022213
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84942111834
Diritti
metadata only access
Soggetti
  • cvc, malpositioning, ...

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback