Scleral fixated intraocular lenses - An angiographic study

LANZETTA, Paolo
•
Menchini U
•
Virgili G
altro
Rapizzi E.
1998
  • journal article

Periodico
RETINA
Abstract
Purpose: We reviewed the results, complications, and fluorescein angiographic (FA) findings in eyes that had undergone transscleral fixation of posterior chamber intraocular lenses (IOLs). Methods: Posterior chamber IOL implantation with scleral fixation was performed on 18 patients. Three patients were aphakic, 14 had an intraoperative posterior capsule rupture during cataract surgery, and one was operated on for a retained lens nucleus and dislocated IOL in the vitreous. Follow-up examinations measured visual acuity, intraocular pressure, and IOL decentration and tilting. In 14 patients, iris and retinal FA were performed. Results: No major complications were noted during the procedure. Mean best-corrected visual acuity was 20/70 preoperatively and 20/30 postoperatively after a mean follow-up of 9.8 months. Fourteen patients achieved a visual acuity of 20/40 or better. Macular epiretinal membranes were diagnosed after surgery in five eyes but only one eye showed significant distortion of the fovea (macular pucker). Iris FA revealed no major vascular abnormalities. Fluorescein angiography showed cystoid macular edema in six cases. Light-induced retinal lesions occurred in six eyes. Conclusions: Transscleral fixation of posterior chamber IOLs provided adequate visual acuity in most patients. Incomplete visual recovery after surgery may be related to the occurrence of macular edema and epiretinal membranes. Light-induced retinal injury was the major irreversible intraoperative complication.
WOS
WOS:000077571900004
Archivio
http://hdl.handle.net/11390/852904
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-0032471873
Diritti
metadata only access
Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback