BACKGROUND AND AIM OF THE STUDY: For patients who require aortic root replacement but are unwilling or unable to receive anticoagulants, a composite conduit was assembled intraoperatively that contained a stented biological valve sutured inside a vascular tube graft, rather than at its extremity. This simple modification of the Bentall concept may provide several advantages. The results obtained with this conduit over an 11-year period were analyzed. METHODS: Between May 2001 and April 2012, 101 consecutive patients (mean age 68.3 +/- 9.2 years) underwent aortic root replacement with the bioprosthetic valved conduit. Aortic pathologies included degenerative disease in 61 patients (60.4%), atherosclerosis in 20 (19.8%), annuloaortic ectasia in 12 (11.9%), porcelain aorta in four (4.0%), and acute dissection in four (4.0%). The whole ascending aorta was replaced in 79 patients (78.2%); a hemiarch reconstruction and a total arch replacement were added in 18 (17.8%) and four (4.0%) patients, respectively. Hypothermic circulatory arrest was performed in 60 cases (59.4%). Forty patients (39.6%) underwent additional cardiac procedures. All perioperative data were collected prospectively. RESULTS: There were five (5.0%) hospital deaths. During a mean follow up of 3.8 +/- 2.4 years there were two non-valve-related cardiac deaths and five noncardiac deaths. The seven-year actuarial survival was 79.2% (95% CI 67.0-91.4%). Bioprosthetic structural dysfunction occurred in only one patient; reoperation was easily performed by replacing the valve within the vascular graft. In the remaining 88 patients (87.1%), echocardiographic assessment showed a low transaortic mean pressure gradient (7.2 +/- 4.7 mmHg) and left ventricular wall mass reduction (p = 0.0002). CONCLUSION: This valved conduit is a safe and durable option for replacing the aortic root, thus facilitating the technique of implantation and simplifying reoperation in the case of valve failure.
WOS
WOS:000330683000008
Archivio
http://hdl.handle.net/11368/2759770
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84891536281
Diritti
metadata only access
Soggetti
  • Aortic root replaceme...

  • stented bioprosthetic...

Scopus© citazioni
3
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback