Uncalibrated Continuous Cardiac Output Measurement in Liver Transplant Patients: LiDCOrapid System versus Pulmonary Artery Catheter

COSTA, Maria Gabriella
•
Chiarandini P
•
Scudeller L
altro
DELLA ROCCA, Giorgio
2014
  • journal article

Periodico
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA
Abstract
Objective: The aim of the study was to assess the level of agreement between continuous cardiac output estimated by uncalibrated pulse-power analysis (PulseCOLiR) and intermittent (ICO) and continuous cardiac output (CCO) obtained using a pulmonary artery catheter (PAC). Design: Prospective cohort study. Setting: University hospital intensive care unit. Participants: Twenty patients after liver transplantation. Intervention: Pulmonary artery catheters were placed in all patients, and ICO and CCO were determined using thermodilution. PulseCOLiR measurements were made using a LiDCOrapidTM (LiDCO Ltd, Cambridge, UK). Measurements and Main Results: ICO data were deter- mined after intensive care unit admission and every 8 hours until the 48th postoperative hour. CCO and PulseCOLiR measurements were recorded simultaneously at these same time intervals as well as hourly. For the 8-hour data set (140 data pairs), the mean bias and percentage errors (PE) were, respectively, 0.10 L/min and 39.2% for ICO versus Pulse- COLiR and 0.79 L/min and 34.6% for CCO versus PulseCOLiR. For the hourly comparison of CCO versus PulseCOLiR (980 data pairs), the bias was 0.75 L/min and the PE 37%. To assess the ability to measure change, a 4-quadrant plot was produced for each pair of methods. The performance of PulseCOLiR was moderate in detecting changes in ICO. Conclusions: In conclusion, the uncalibrated PulseCOLir method should not be used as a substitute for the thermo- dilution technique for the monitoring of cardiac output in liver transplant patients.
DOI
10.1053/j.jvca.2013.12.027
WOS
WOS:000338090500018
Archivio
http://hdl.handle.net/11390/902313
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84902183038
Diritti
closed access
Soggetti
  • Cardiac output

  • Monitoring

  • intensive care

  • liver transplantation...

  • thermodilution

Scopus© citazioni
18
Data di acquisizione
Jun 2, 2022
Vedi dettagli
Web of Science© citazioni
24
Data di acquisizione
Mar 28, 2024
Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback