Changes of intracardiac flow dynamics measured by HyperDoppler in patients with aortic stenosis

Sabatino J.
•
Leo I.
•
Strangio A.
altro
De Rosa S.
2024
  • journal article

Periodico
EUROPEAN HEART JOURNAL OPEN
Abstract
Aims Assessment of intracardiac flow dynamics has recently acquired significance due to the development of new measurement methods based on echocardiography. Recent studies have demonstrated that cardiac abnormalities are associated with changes in intracardiac vortical flows. Yet, no previous study assessed the impact of aortic stenosis (AS) on intracardiac vortices. This study aims to explore the clinical potential of additional information provided by quantifying intracardiac flow dynamics in patients with AS. Methods and results One hundred and twenty patients with severe AS, sixty patients with concentric ventricular remodelling (VR), and hundred controls (CTRL) were prospectively included and underwent non-invasive evaluation of intracardiac flow dynamics. In addition to standard echocardiography, fluid dynamics were assessed by means of HyperDoppler. Vortex depth (P < 0.001), vortex length (P = 0.003), vortex intensity (P < 0.001), and vortex area (P = 0.049) were significantly increased in AS compared with CTRL. In addition, mean energy dissipation was significantly higher in AS compared with CTRL (P < 0.001) and VR (P = 0.002). At receiver operating characteristic analysis, vortex depth showed the best discrimination capacity for AS (P < 0.001). Conclusion Changes in fluid dynamics-based HyperDoppler indices can be reliably assessed in patients with AS. Significant changes in vortex depth and intensity can selectively differentiate AS from both concentric remodelling and healthy CTRLs, suggesting that the assessment of intracardiac flow dynamics may provide complementary information to standard echocardiography to better characterize patients' subsets.
DOI
10.1093/ehjopen/oeae069
WOS
WOS:001472196600020
Archivio
https://hdl.handle.net/11368/3096394
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85203059090
https://academic.oup.com/ehjopen/article/4/5/oeae069/7730191
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
FVG url
https://arts.units.it/bitstream/11368/3096394/1/oeae069.pdf
Soggetti
  • Aortic stenosi

  • Fluid dynamic

  • Vortices

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback