Logo del repository
  1. Home
 
Opzioni

Accuracy of visual analysis vs. apparent diffusion coefficient quantification in differentiating solid benign and malignant focal liver lesions with diffusion-weighted imaging.

GIROMETTI, Rossano
•
Del Pin M
•
Pullini S
altro
ZUIANI, Chiara
2013
  • journal article

Periodico
LA RADIOLOGIA MEDICA
Abstract
PURPOSE: The authors compared the accuracy of diffusion-weighted imaging (DWI) visual analysis (VA) vs. apparent diffusion coefficient quantification (ADC-Q) in assessing malignancy of solid focal liver lesions (FLLs). MATERIALS AND METHODS: Using a 1.5-T system, two radiologists retrospectively assessed as benign or malignant 50 solid FLLs: (a) by VA of signal intensity on DWI images at b=800 s/mm(2) and ADC map; (b) by quantifying lesion ADC. Reference standard included histology or follow-up confirmation of diagnosis by a consensus panel. Receiver operating characteristic (ROC) curve analysis was performed. RESULTS BECAUSE OF 20 FALSE-NEGATIVE HEPATOCELLULAR CARCINOMAS, VA SHOWED LOWER ACCURACY THAN ADC-Q (52.0% VS. 68.0%). HOWEVER, STRATIFIED ACCURACY FOR METASTASES WAS HIGHER WITH VA (75.0 VS. 66%). ADC AND SIGNAL FEATURES OF MALIGNANT AND BENIGN FLLS WERE FOUND TO LARGELY OVERLAP: CONCLUSIONS: VA performed worse than ADC-Q for hepatocellular carcinoma and better for metastases. Overall, the accuracy of both methods was limited because of the overlap in visual appearance and ADC values between solid benign and malignant FLLs.
DOI
10.1007/s11547-012-0873-z
WOS
WOS:000317668300001
Archivio
http://hdl.handle.net/11390/867854
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84877875662
Diritti
metadata only access
Soggetti
  • Diffusion-weighted Im...

  • Focal liver lesion

  • ADC quantification

Scopus© citazioni
16
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
15
Data di acquisizione
Mar 24, 2024
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback