Logo del repository
  1. Home
 
Opzioni

Phacoemulsification Wound Burn and Its Management

Giglio, Rosa
•
Vinciguerra, Alex Lucia
•
Inferrera, Leandro
•
Tognetto, Daniele
2024
  • journal article

Periodico
CASE REPORTS IN OPHTHALMOLOGY
Abstract
Introduction: The production of ultrasonic energy during phacoemulsification is associated with heat generation that could damage ocular tissues, particularly at the corneoscleral wound site. Case presentation: This study presents an 89-year-old patient with senile hypermature cataract and Fuchs endothelial dystrophy developing severe thermal corneoscleral injury during phacoemulsification. At presentation, visual acuity was finger count at 40 cm and there was a 1 × 2-mm area of corneal melting at the corneal tunnel with diffuse corneal oedema. After 1 month, a temporal circular corneal patch graft was applied to the corneal burn. A penetrating keratoplasty was performed 16 months after the first surgery. Conclusion: Corneal surgery, including lamellar patch grafts and full-thickness penetrating grafts, could be used, when necessary, to restore the cornea's integrity. These procedures could eliminate corneal scarring, decrease astigmatism, and improve vision in patients with phacoemulsification burns.
DOI
10.1159/000537741
WOS
WOS:001201798800001
Archivio
https://hdl.handle.net/11368/3073642
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85190533633
https://karger.com/cop/article/15/1/303/898052/Phacoemulsification-Wound-Burn-and-Its-Management
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11001284/
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by-nc/4.0/
FVG url
https://arts.units.it/bitstream/11368/3073642/1/Phacoemulsification Wound Burn and Its Management .pdf
Soggetti
  • Cataract extraction

  • Penetrating keratopla...

  • Phacoemulsification

  • Thermal injury

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback