Logo del repository
  1. Home
 
Opzioni

Hydrophobic acrylic versus heparin surface-modified polymethylmethacrylate intraocular lens: a biocompatibility study.

TOGNETTO, DANIELE
•
Toto L
•
Minutola D.
altro
RAVALICO, GIUSEPPE
2003
  • journal article

Periodico
GRAEFE'S ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
Abstract
Background: The implant of intraocular lenses (IOLs) following cataract surgery induces a foreign-body reaction to the IOL and a response on the part of the lens epithelial cells (LECs). The purpose of this study was to compare these aspects after the implantation of two different IOL materials. Methods: Thirty-six cataract patients were randomised to receive two different foldable lens: an acrylic hydrophobic IOL (Acrysof MA30BA) and a heparin surface-modified (HSM) polymethylmethacrylate IOL (Pharmacia & Upjohn 809C) after phacoemulsification. Slit-lamp biomicroscopy with specular technique was used to assess the inflammatory cell adhesion on the anterior IOL surface, anterior capsule opacification (ACO) and membrane growth from the rhexis edge at 7, 30, 90, 180 and 360 days after surgery. Results: The 809C group showed a higher percentage of patients with slight inflammatory cell adhesion on the anterior cell surface and a higher small cellular density during the whole follow-up period. The epithelioid cell response was greater in the 809C group than the Acrysof group but the difference between the two groups was not statistically significant. The ACO increased during the follow-up in both groups but was significantly higher in the 809C group. Conclusion: Acrysof lenses are more biocompatible than HSM IOLs, showing a lower grade of inflammatory cell adhesion and ACO. The implantation of these lenses may be particularly indicated in patients with pathologies predisposing to blood-aqueous barrier damage.
DOI
10.1007/s00417-003-0711-z
WOS
WOS:000185601900005
SCOPUS
2-s2.0-0141850899
Archivio
http://hdl.handle.net/11368/1700263
Diritti
metadata only access
Soggetti
  • :POSTERIOR CAPSULE OP...

  • COLLAGEN TYPE-IV

  • POSTOPERATIVE INFLAMM...

  • HUMAN AUTOPSY EYES

  • POLY(METHYL METHACRYL...

  • CELLULAR REACTION

  • ANTERIOR SURFACE

  • AQUEOUS FLARE

  • IN-VITRO

  • ADHESION

Web of Science© citazioni
20
Data di acquisizione
Mar 25, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback