Logo del repository
  1. Home
 
Opzioni

An ultrasonographic method to measure the sensitivity of the baroreflex in clinical practice: application to pharmacological studies.

CARRETTA, RENZO
•
BARDELLI, MORENO
•
BULLI G
altro
CAMPANACCI L.
1991
  • journal article

Periodico
JOURNAL OF HYPERTENSION SUPPLEMENT
Abstract
To determine whether it is possible to assess baroreceptor sensitivity by measuring changes in blood velocity in the carotid artery and changes in the heart rate, we performed a series of 108 experiments in 19 hypertensives aged 20-57 years (mean 46.6 +/- 8.6). In each experiment, we took simultaneous measurements of carotid artery blood flow velocity (Doppler technique), the brachial intra-arterial blood pressure and the heart rate, during a rapid and transient increase in blood pressure induced by injections of phenylephrine. We then calculated the maximum slope of the regression lines correlating blood velocity with the heart period (Trieste method) and blood pressure with the heart period (Oxford method). We obtained good accuracy from the Trieste method compared with the Oxford method, as assessed by the mean of the sum of the squares (difference + 5\%, NS). After the administration of 4 mg oral lacidipine to 13 essential hypertensives, aged 37-54 years (47.6 +/- 5.3), baroreflex sensitivity was not changed, as assessed by either method (Oxford method 10.1 +/- 5.5 versus 9.8 +/- 6.2 ms/mmHg; Trieste method - 0.57 +/- 0.32 versus - 0.49 +/- 0.31 ms/Hz). The coefficients of variation for the two methods, calculated for the measurements taken before and after the administration of lacidipine, were not statistically different (Oxford method 25.0 +/- 18.4 versus 36.2 +/- 16.0; Trieste method 36.7 +/- 19.2 versus 39.7 +/- 19.2). The new non-invasive Trieste method thus showed the same accuracy and precision as the invasive Oxford method in measuring baroreflex sensitivity and can be used in pharmacological studies.
WOS
WOS:A1991HD14600008
Archivio
http://hdl.handle.net/11368/2635610
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-0026343518
http://www.scopus.com/inward/record.url?eid=2-s2.0-0026343518&partnerID=40&md5=ebed3c6e1f95928ef5ad11806e2ba8e9
Diritti
metadata only access
Soggetti
  • Antihypertensive Agen...

  • diagnostic use, Blood...

  • physiology, Carotid A...

  • physiology, Dihydropy...

  • diagnostic use, Heart...

  • physiology, Humans, H...

  • physiopathology/ultra...

  • diagnostic use, Press...

  • physiology, Reflex

  • physiology, Reproduci...

  • methods

Scopus© citazioni
6
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback