Logo del repository
  1. Home
 
Opzioni

Association between echocardiography-derived haemodynamic force parameters and left ventricular reverse remodelling after cardiac resynchronization therapy

Dorien Laenens
•
Pieter van der Bijl
•
Xavier Galloo
altro
Jeroen J Bax
2024
  • journal article

Periodico
EUROPEAN HEART JOURNAL. CARDIOVASCULAR IMAGING
Abstract
Aims: Cardiac resynchronization therapy (CRT) may induce left ventricular (LV) reverse remodelling (=LV response) in patients with heart failure. Intraventricular pressure gradients can be quantified using echocardiography-derived haemodynamic forces (HDF). The aim was to evaluate the association between baseline HDF and LV response and to compare the change of HDF after CRT between LV responders and LV non-responders. Methods and results: The following HDF parameters were assessed: 1)apical-basal (AB) strength, 2)lateral-septal strength, 3)force vector angle, 4)systolic AB impulse, 5)systolic force vector angle. LV response was defined as a reduction of LV end-systolic volume ≥15% at six months. One hundred ninety-six patients were included (64±11 years, 122(62%) men), 136(69%) showed LV response. On multivariable logistic regression analysis, the force vector angle in the complete heart cycle (OR 1.083 (95%CI 1.018, 1.153), p=0.012) and the systolic force vector angle (OR 1.089 (95%CI 1.021, 1.161), p=0.009), both included in separate models, were independently associated with LV response. Six months after CRT, LV responders had greater AB strength, AB impulse and higher force vector angles, while LV non-responders only showed improvement in the force vector angle in the complete heart cycle. Conclusion: The orientation of HDF at baseline is associated with LV response to CRT. Six months after CRT, the orientation of HDF improves in LV responders and LV non-responders, while the magnitude of AB HDF only improves in LV responders.
DOI
10.1093/ehjci/jeae181
WOS
WOS:001285548100001
Archivio
https://hdl.handle.net/11368/3096393
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85211392288
https://academic.oup.com/ehjcimaging/article/25/12/1721/7715806
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
FVG url
https://arts.units.it/bitstream/11368/3096393/1/2024ijacc.pdf
Soggetti
  • Fluid dynamic

  • cardiac resynchroniza...

  • haemodynamic force

  • left ventricular reve...

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback