Logo del repository
  1. Home
 
Opzioni

“Comparison between spinal anaesthesia and sciatic-femoral block for arthroscopic knee surgery.”

SPASIANO A
•
FIORE I
•
PESAMOSCA A
•
DELLA ROCCA, Giorgio
2007
  • journal article

Periodico
MINERVA ANESTESIOLOGICA
Abstract
We compared spinal anesthesia and sciatic-femoral block for arthroscopic knee surgery in terms of hemodynamic changes, intraoperative anesthesia, postoperative analgesia, postoperative motor block and bladder function, side effects, and patient satisfaction. METHODS: Thirty-two patients were randomised into 2 groups: Group B (sciatic-femoral block with mepivacaine 1% 15 + 25 mL, 120 mm/35 mm 22-gauge needles and ElectroNerve Stimulator) and Group S (unilateral spinal anesthesia with 7 mg of hyperbaric bupivacaine 0.5% and 25-gauge Sprotte needle in L2-L3 space). We recorded pain, together with hemodynamic parameters (baseline, 5, 10, 15, 30 min), utilising Numerical Rating Scale (NRS) during the tourniquet application and during the surgical procedures, anesthesia quality, orthopedic evaluation for intraoperative liberty of knee movement. During the postoperative period we recorded at 2, 4 and 6 h: postoperative analgesia, motor block, first urine output, side effects, first requirement for analgesic drug, patient satisfaction and costs. RESULTS: The only significant differences between the 2 groups (P<0.05) were the heart rate changes at 10, 15, 30 min with an increase in Group B and a decrease in Group S, and the first urine output at 200+/-69 min in Group B versus 269+/-66 min in Group S. CONCLUSION: In conclusion the sciatic-femoral nerve block is a valid alternative to spinal anesthesia for arthroscopic knee surgery, leading to a faster discharging from the hospital.
WOS
WOS:000244539100002
Archivio
http://hdl.handle.net/11390/688769
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-34147189170
Diritti
closed access
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback