Logo del repository
  1. Home
 
Opzioni

Investigating the Effect of Different Scenarios of Hand-Arm Vibration on the Vascular Response of the Hand

Mohsen Aliabadi
•
Seyed Hojat Mousavi Kordmiri
•
Rostam Golmohammadi
altro
Maryam Farhadian
2024
  • journal article

Periodico
MAJALLAH-I DANISHKADAH-I PIZISHKI-I ISFAHAN
Abstract
Background: The increasing use of manual vibrating equipment for various construction works has exposed the workers of this industry to hand-arm vibration. The present study investigates the effect and frequency of hand-arm vibration on the vascular response of the hand in construction workers. Methods: The present study was conducted on 40 workers in the construction industry in the laboratory phase. Using the hand-arm vibration simulator, the participants were exposed to 4 different scenarios of hand-arm vibration 5 m/s2 (125Hz), 5 m/s2 (63Hz), 5 m/s2 (31.5Hz), and 10 m/s2 (31.5Hz). Before and after each scenario, the hand's vascular response was analyzed to detect the degree of vascular obstruction using the Nexus-4 device along with the BVP sensor. Findings: The results of the present study showed that the relative blood flow of the finger decreased in all scenarios of exposure to hand-arm vibration and had statistically significant changes. The mean difference of the relative blood flow of the finger in the exposure to hand-arm vibration 10 m/s2 (31.5Hz) was more than other scenarios. Examining the scenarios with the same vibration acceleration of 5 m/s2 and different frequencies of 125, 63, and 31.5 Hz showed that with increasing frequency, the amount of relative blood flow decreased. Conclusion: The frequency of exposure to hand-arm vibration, like the acceleration encountered, is fundamental very important in causing vascular complications. The higher the frequency of hand-arm vibration, the more vascular disorders in the fingers.
DOI
10.48305/jims.v42.i763.0280
Archivio
https://hdl.handle.net/11368/3084778
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85200768544
https://jims.mui.ac.ir/article_31229.html?lang=en
Diritti
closed access
license:digital rights management non definito
license uri:iris.pri00
FVG url
https://arts.units.it/request-item?handle=11368/3084778
Soggetti
  • Hand-arm vibration sy...

  • Regional blood flow

  • Construction industry...

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback