Logo del repository
  1. Home
 
Opzioni

Idiopathic macular hole surgery with low-concentration infracyanine green-assisted peeling of the internal limiting membrane

LANZETTA, Paolo
•
POLITO A
•
DEL BORRELLO M
altro
BANDELLO F.
2006
  • journal article

Periodico
AMERICAN JOURNAL OF OPHTHALMOLOGY
Abstract
PURPOSE: To evaluate the efficacy of pars plana vitrectomy with infracyanine green (IFCG)-assisted internal limiting membrane peeling for the treatment of idiopathic macular hole. DESIGN: Prospective, noncomparative interventional case series. METHODS: Thirty-eight consecutive eyes of 35 patients with idiopathic macular hole were included in the study. Patients underwent early treatment diabetic retinopathy (ETDRS) visual acuity examination, dilated ophthalmoscopy, and optical coherence tomography before treatment and during follow,up. Fluorescein angiography was done in selected cases. Patients underwent a three-port pars plana vitrectomy with complete posterior hyaloid and epiretinal membrane removal. The internal limiting membrane (ILM) was stained with 0.5 cc of IFCG (0.5 mg/ml, 308 mOsm) and peeled up to the vascular arcades. Perfluoropropane gas (Us) 10% was used as tamponade. RESULTS: Mean follow-up duration was 10 5 months (range, 3 to 24 months). Six eyes had stage 2 macular hole, 15 eyes stage 3, and 16 eyes stage 4. Overall, 37 of 38 macular holes closed after a single surgery. Median visual acuity was 20/100 (range, 20/400 to 20/50) before surgery and 20/50 (range, 20/640 to 20/25) after surgery. Visual acuity after surgery was 20/50 or better in 24 of 38 (63.1%) eyes. Twenty,five (65.8%) eyes improved by 2 or more lines, nine (23.7%) eyes were stable, and four (10.5%) eyes worsened by 2 or more lines. CONCLUSIONS: This study suggests that IFCG (0.05%) effectively stains the ILM with apparent safety, and that IFCG-assisted peeling of the ILM may be useful in the treatment of idiopathic macular hole.
WOS
WOS:000242142900009
Archivio
http://hdl.handle.net/11390/699641
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-33750036394
Diritti
closed access
Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback