Logo del repository
  1. Home
 
Opzioni

Suture of Symptomatic YAG Laser Peripheral Iridotomies Following Phakic Intraocular Lens Implantation

TOGNETTO, DANIELE
•
DE GIACINTO, CHIARA
•
CIRIGLIANO, GABRIELLA
2017
  • journal article

Periodico
JOURNAL OF GLAUCOMA
Abstract
A 45-year-old woman complained of glare and photophobia after iris-fixated phakic intraocular lens (IFPIOL) implantation in her left eye. The patient underwent prophylactic laser peripheral iridotomies (LPIs) 2 days before surgery. The uncorrected visual acuity after surgery was 20/20 and the intraocular pressure was 14mmHg. The slit-lamp examination showed a wellcentered IFPIOL and 2 LPIs at 10 and 2 o’clock partially covered by the upper lid. Twenty days after IFPIOL implantation, as symptoms persisted and were intolerable to the patient, we decide to suture iridotomies using a modified Siepser slip-knot technique. Postoperatively, visual acuity remains 20/20 and patient reported a complete disappearance of symptoms. No intraoperative and postoperative complications were noted. Experiencing glare and photophobia is a rare side effect due to LPI. Suture of iridotomies using a modified Siepser slip-knot technique can be considered a safe and effective procedure to solve this annoying complication.
DOI
10.1097/IJG.0000000000000688
WOS
WOS:000404661900015
Archivio
http://hdl.handle.net/11368/2904711
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85019666771
http://journals.lww.com/glaucomajournal/Abstract/2017/07000/Suture_of_Symptomatic_YAG_Laser_Peripheral.15.aspx
Diritti
closed access
license:digital rights management non definito
FVG url
https://arts.units.it/request-item?handle=11368/2904711
Soggetti
  • phakic intraocular le...

  • symptomatic periphera...

  • iridotomy suture

  • Siepser slip-knot tec...

Scopus© citazioni
2
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Web of Science© citazioni
2
Data di acquisizione
Mar 25, 2024
Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback