Logo del repository
  1. Home
 
Opzioni

Optimization of the energy for Breast monochromatic absorption X-ray Computed Tomography

Delogu, Pasquale
•
Di Trapani, Vittorio
•
Brombal, Luca
altro
Oliva, Piernicola
2019
  • journal article

Periodico
SCIENTIFIC REPORTS
Abstract
The limits of mammography have led to an increasing interest on possible alternatives such as the breast Computed Tomography (bCT). The common goal of all X-ray imaging techniques is to achieve the optimal contrast resolution, measured through the Contrast to Noise Ratio (CNR), while minimizing the radiological risks, quantified by the dose. Both dose and CNR depend on the energy and the intensity of the X-rays employed for the specific imaging technique. Some attempts to determine an optimal energy for bCT have suggested the range 22keV–34keV, some others instead suggested the range 50keV–60keV depending on the parameters considered in the study. Recent experimental works, based on the use of monochromatic radiation and breast specimens, show that energies around 32keV give better image quality respect to setups based on higher energies. In this paper we report a systematic study aiming at defining the range of energies that maximizes the CNR at fixed dose in bCT. The study evaluates several compositions and diameters of the breast and includes various reconstruction algorithms as well as different dose levels. The results show that a good compromise between CNR and dose is obtained using energies around 28keV.
DOI
10.1038/s41598-019-49351-2
WOS
WOS:000485216000005
Archivio
http://hdl.handle.net/11368/2948835
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85072116490
https://www.nature.com/articles/s41598-019-49351-2#article-info
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by-nc-nd/4.0/
FVG url
https://arts.units.it/bitstream/11368/2948835/1/delogu_2019.pdf
Soggetti
  • Breast CT

  • Energy Optimization

  • Contrast to noise rat...

  • Monochromatic

Scopus© citazioni
9
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Web of Science© citazioni
10
Data di acquisizione
Mar 24, 2024
Visualizzazioni
7
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback