Fire Resistance of In-Plane Compressed Log-House Timber Walls with Partial Thermal Insulation

Bedon, Chiara
•
Fragiacomo, Massimo
2018
  • journal article

Periodico
BUILDINGS
Abstract
This paper presents the full-scale experimental assessment of a log-house timber wall with partial thermal insulation under in-plane compression and exposed to fire on one side. A key aspect of the current design application for log-house systems is represented by geometrical details, like cross-sectional properties of logs (typically characterised by high depth-to-width ratios) and outriggers. The latter provides restraint condition for the examined walls and hence markedly affects their overall load-carrying capacity. As a result, careful consideration should be given to the choice of these details, compared to fully monolithic timber walls (i.e., made from cross-laminated timber), due to the possible occurrence of local structural and/or thermo-mechanical mechanisms. This is the case of exceptional loading conditions like fire load, as the fire resistance of these systems could be affected by a multitude of variables, including the presence (even though limited to few surfaces only) of thermal insulation panels. To this aim, the results of a full-scale furnace test are discussed in the paper for a log-wall with partial thermal insulation, namely thermal insulation applied on the outriggers only, under the effects of EN/ISO standard fire conditions. The results of Finite Element (FE) numerical studies are also reported, to further explore the load-carrying performance of the reference log-house specimen and compare it with the experimental observations. Several thermal insulation configurations are finally numerically investigated, showing their effects on the overall fire resistance of the assembly. In accordance with literature, the test shows that the log house’s timber wall is suitable to obtain a fire resistance of about 60 min under relevant loading. The FE results are in rather close agreement with the temperature measurements within the section of logs, as well as a qualitative correlation with respect to the mechanical behaviour observed in the full-scale furnace experiment. The key role of outriggers and their thermo-mechanical boundaries, finally, is emphasised.
DOI
10.3390/buildings8100131
WOS
WOS:000448542700002
Archivio
http://hdl.handle.net/11368/2929485
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85055353937
http://www.mdpi.com/2075-5309/8/10/131
Diritti
open access
FVG url
https://arts.units.it/bitstream/11368/2929485/5/buildings-.pdf
Soggetti
  • log-house wall

  • in-plane compression

  • fire resistance

  • full-scale standard t...

  • Finite Element (FE) a...

  • thermal insulation

  • gypsum fibreboard pan...

  • FE parametric study

Scopus© citazioni
4
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Web of Science© citazioni
5
Data di acquisizione
Mar 28, 2024
Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback